Chapter 14
14-27
14.3.9 Points to Note When Replacing the reader
controller PCB
0008-3977
iR105i/iR105+ / iR9070
1) Execute the following two items in service mode to print out settings
stored under items: COPIER> FUNCTION> MISC-P> LBL-PRNT
and COPIER> FUNCTION> MISCP> USER-PRT.
2) Check to make sure that the Execute/Memory lamp in the control
panel is OFF, and turn off the main power switch.
3) Disconnect the power plug from the power outlet.
The machine remains powered as long as the power plug is connected.
Be sure to disconnect the power plug from the wall outlet.
4) Replace the reader controller PCB.
5) Assemble the machine, and connect the power plug to the power
outlet; then, turn on the main power switch.
6) Execute the following in service mode: COPIER> FUNCTION>
CLEAR> R-CON.
7) Turn off and then on the main power switch.
8) Execute the following in service mode: COPIER> FUNCTION>
CCD> CCD-ADJ.
9) Enter the settings printed out in step 1) for the following:
- service mode
COPIER> ADJUST> ADJ-XY (4 items)
COPIER> ADJUST> LAMP (1 item)
COPIER> ADJUST> CCD (29 items)
- user mode
10) Turn off and then on the main power switch, and execute the
following in service mode
to generate a service label; keep the service label in the service book
case: COPIER> FUNCTION> MISC-P> LBL-PRNT.
14.3.10 When Replacing the Reader Controller PCB
0008-8449
1) Execute the following in service mode to generate the setting of each
item: COPIER, FUNCTION>MISC-P>LBL-PRNT and
COPIER>FUNCTION>MISC-P>USER-PRT.
2) Check to make sure that that Execute/Memory lamp in the control
panel are OFF, and turn off the main power switch.
3) Disconnect the power plug from the power outlet.
The machine remains supplied with power as long as its power plug is
connected to a power outlet even when its main power switch is turned
off. Be sure to disconnect the power plug.
4) Replace the reader controller PCB.
5) After assembling the machine, connect the power plug to the power
outlet, and turn on the main power switch.
6) Execute the following in service mode:
COPIER>FUNCTION>CLEAR>
R-CON
.
7) Turn on and then off the main power switch.
8) Execute the following in service mode:
COPIER>FUNCTION>CCD>
CCD-ADJ
.
9) Enter the setting of each item generated in step 1):
- Service Mode
COPIER>ADJUST>ADJ-XY (4 items)
COPIER>ADJUST>LAMP (1 item)
COPIER>ADJUST>CCD (29 items)
- User Mode
10) Turn off and then on the main power switch, and execute
COPIER>FUNCTION>MISC-P>LBL-PRNT in service mode to
generate a service label. Then, store it in the service book case.
14.3.11 When Replacing the Reder controller PCB
0008-8451
/ iR8070
1) Print out the data of user mode/service mode.
2) Check to make sure that the Execute/Memory lamp in the control
panel ore OFF, and turn off the main power switch.
3) Disconnect the power plug from the power outlet.
The machine remains supplied with power as long as its power plug is
connected to a power outlet even when is main power switch is turned
off.
Be sure to disconnect the power plug.
4) Replace the reader controller PCB.
5) Remove the EEPROM (1 pc.) from the existing PCB, and mount it to
the new PCB.
6) After assembling the machine, connect the power plug to the power
outlet, and turn on the main power switch.
7) Check to make sure that the following service mode settings are the
same as the data before replacement:
COPIER>ADJUST>AE>all items
COPIER>ADJUST>ADJ-XY>all items
COPIER>ADJUST>CCD>all items
If any service mode setting is faulty, enter the respective setting
recorded on the service label in service mode.
Summary of Contents for ImageRunner iR8500 Series
Page 1: ...Apr 5 2005 Service Manual iR8500 Series ...
Page 2: ......
Page 6: ......
Page 32: ...Contents ...
Page 33: ...Chapter 1 Introduction ...
Page 34: ......
Page 98: ......
Page 99: ...Chapter 2 Installation ...
Page 100: ......
Page 180: ...Chapter 2 2 78 F 2 272 2 1 1 3 ...
Page 181: ...Chapter 3 Basic Operation ...
Page 182: ......
Page 184: ......
Page 207: ...Chapter 4 Main Controller ...
Page 208: ......
Page 245: ...Chapter 4 4 35 F 4 72 1 2 ...
Page 246: ......
Page 247: ...Chapter 5 Original Exposure System ...
Page 248: ......
Page 252: ......
Page 306: ......
Page 307: ...Chapter 6 Image Processing System ...
Page 308: ......
Page 310: ......
Page 319: ...Chapter 7 Laser Exposure ...
Page 320: ......
Page 322: ......
Page 335: ...Chapter 8 Image Formation ...
Page 336: ......
Page 340: ......
Page 399: ...Chapter 9 Pickup Feeding System ...
Page 400: ......
Page 404: ......
Page 482: ......
Page 483: ...Chapter 10 Fixing System ...
Page 484: ......
Page 524: ......
Page 525: ...Chapter 11 External and Controls ...
Page 526: ......
Page 530: ......
Page 583: ...Chapter 12 MEAP ...
Page 584: ......
Page 586: ......
Page 589: ...Chapter 13 Maintenance and Inspection ...
Page 590: ......
Page 592: ......
Page 610: ...Chapter 13 13 18 F 13 17 1 2 3 ...
Page 648: ......
Page 649: ...Chapter 14 Standards and Adjustments ...
Page 650: ......
Page 654: ......
Page 723: ...Chapter 15 Correcting Faulty Images ...
Page 724: ......
Page 728: ......
Page 792: ......
Page 793: ...Chapter 16 Self Diagnosis ...
Page 794: ......
Page 796: ......
Page 841: ...Chapter 17 Service Mode ...
Page 842: ......
Page 1076: ......
Page 1077: ...Chapter 18 Upgrading ...
Page 1078: ......
Page 1080: ......
Page 1108: ...Chapter 18 18 28 F 18 45 3 Click Start F 18 46 4 Click Save F 18 47 5 Click OK ...
Page 1111: ...Chapter 19 Service Tools ...
Page 1112: ......
Page 1114: ......
Page 1120: ......
Page 1121: ...Apr 5 2005 ...
Page 1122: ......