Configuring the Mannequin
55
1. Connect the provided 140 mL syringe to the air tube on the uterus.
NOTE:
Leave the syringe attached during preparation and installation.
The Syringe Air Tube Connection
2. Depress and pull the syringe plunger until uterus inflates to a rounded
shape (approximately 10 times).
3. Lubricate the inside of the vaginal canal with cottonseed oil.
4. Use one hand to gently squeeze the uterus. Use the other hand to reach in
the vaginal canal and grab the internal liner (squeezing the uterus creates
air pressure to help pull out the liner).
TIP:
A second person holding the uterus may be helpful.
The Invertible Uterus
The air
tube