Configuring the Mannequin
29
Loading the Fetus - Delivery
NOTE:
Prior to loading the fetus, ensure that the descent mechanism is properly returned to the
“Home” position. Failure to do so will require the user to reload the fetus.
To manually return the rotation ring to the Home position:
1. Press the upward arrow button on the Gripper button pad.
The Gripper Button Pad
2. Hold for three seconds after the rotation ring reaches the top of the descent
mechanism and wait until the rotation ring rotates to the “Home” position.
3. Ensure there are no kinks in the yellow tubing on the rotation ring.
NOTE:
If the SCE does not require loading a fetus, ensure the descent
mechanism is retracted to the most superior position prior to running the SCE.
Vaginal Delivery - Breech
To load the delivery fetus for a vaginal delivery in a breech presentation:
1. Ensure the rotation ring from inside the mannequin’s torso is installed and
returned to the “Home” position.
2. Ensure the delivery uterine funnel with dynamic cervix is installed.
3. Ensure the fetus is powered on, indicated by the illuminated power light in
the umbilical opening on the front of the fetus.
4. Ensure the umbilical cord is connected to the fetus.
The
upward
arrow
icon
Summary of Contents for Fidelis Lucina
Page 1: ...User Guide Maternal Fetal Simulator...
Page 2: ...2015 CAE Healthcare 905K470052 v2 1...
Page 28: ...Table Of Contents xxvi This page intentionally blank...
Page 36: ...Equipment Overview 8 This page intentionally blank...
Page 190: ...Using M se 162 This page intentionally blank...
Page 226: ...Using the TouchPro CTG Monitor 198 This page intentionally blank...
Page 266: ...Using Lucina 238 This page intentionally blank...
Page 298: ...Care and Maintenance 270 This page intentionally blank...
Page 389: ......