Müse Parameter Descriptions
279
Respiratory Rate Factor
The
Respiratory Rate Factor
parameter (along with the
Tidal Volume Factor
parameter) is used to
change the baseline respiratory rate (before the control-of-breathing and drug influences are taken
into account). A value of 2 doubles the baseline respiratory rate. A value of 0.5 decreases the baseline
respiratory rate by 50%. Changing the respiratory rate using this parameter maintains the physiological
models.
Default
: 1
Range
: 0.01 - 6.00
TIP
: First decrease the respiratory gain factor to reduce the influence of the respiratory control
mechanism on the respiratory rate and tidal volume.
Shunt Fraction
The
Shunt Fraction
parameter is frequently used to assist in desaturating a patient. This parameter
creates a physiologic “bypass” of the normal pulmonary circulation, resulting in changes in O
2
, CO
2
and
anesthetic gases at the alveolar level. Typically, values of 0.1 to 0.4 are needed to create large alveolar-
arterial oxygen gradients sufficient to cause arterial hypoxemia.
Default
: 0.02
Range
: 0.00 - 0.50
TIP
: If the parameter is set high (0.5), the patient desaturates rapidly and responds negatively to the
administration of supplemental O
2
.
SpO
2
The SpO
2
parameter is used to override the normal pulmonary circulation and set the SpO
2
at a fixed
numeric value, regardless of the oxygen applied. Resetting to
Modeled
returns control of the
underlying SpO
2
to the physiological models. If SpO
2
is set to less than 75%, the eyes will automatically
close when in the Auto mode.
Default:
Modeled
Range:
0% - 100%
Summary of Contents for Fidelis Lucina
Page 1: ...User Guide Maternal Fetal Simulator...
Page 2: ...2015 CAE Healthcare 905K470052 v2 1...
Page 28: ...Table Of Contents xxvi This page intentionally blank...
Page 36: ...Equipment Overview 8 This page intentionally blank...
Page 190: ...Using M se 162 This page intentionally blank...
Page 226: ...Using the TouchPro CTG Monitor 198 This page intentionally blank...
Page 266: ...Using Lucina 238 This page intentionally blank...
Page 298: ...Care and Maintenance 270 This page intentionally blank...
Page 389: ......