Müse Parameter Descriptions
277
Intracranial Pressure (ICP)
The ICP parameter is used to set the ICP displayed as a numeric value on Patient Status Display and on
the TouchPro Patient monitor. The value is
Modeled
by default.
Default
: Modeled
Range:
0 mmHg - 65.0 mmHg
Neuromuscular Blockade (NMB)
The pharmacokinetic and pharmacodynamic models based on the neuromuscular blocking agents
administered and the time course of their injection automatically determines the degree of NMB. For
some educational applications, however, the instructor may wish to set a fixed degree of
neuromuscular blockade that remains stable for an indefinite period. This can be accomplished using
the
NMB
parameter. The default setting instructs the pharmacologic models to determine the degree
of neuromuscular blockade based upon the drugs injected and their pharmacologic properties.
When a numeric value is assigned to this parameter, the degree of NMB is set to that level. For example,
80% NMB causes the simulator to set the degree of NMB to 80%, regardless of the presence (or
absence) of neuromuscular blocking drugs. Clinically, the spontaneous tidal volume is markedly
reduced. If NMB is set to greater than 30%, the eyes will automatically close when in the Auto mode.
Default
: Modeled
Range:
0% - 100%
Temperature: Body
The temperature measured at the body surface can be set using this parameter and can be displayed
on the Patient Status Display and TouchPro software.
The body temperature is not linked to the physiologic models. However, changes can be made “on the
fly” or scripted using the Scenario Designer.
Default
: 36.5° C
Range
: 32.0° C - 42.0° C
Temperature: Blood
The arterial blood temperature can be set using the
Temperature: Blood
parameter. The arterial blood
temperature can then be displayed on the Patient Status Display and TouchPro software. Note that
changes in arterial temperature may alter the position of the standard oxyhemoglobin dissociation
curve (shift). As temperature increases or pH decreases, more oxygen is released from hemoglobin and
thus the patient’s saturation decreases. The inverse is also true.
Default
: 37° C
Range
: 32.0° C - 42.0° C
Summary of Contents for Fidelis Lucina
Page 1: ...User Guide Maternal Fetal Simulator...
Page 2: ...2015 CAE Healthcare 905K470052 v2 1...
Page 28: ...Table Of Contents xxvi This page intentionally blank...
Page 36: ...Equipment Overview 8 This page intentionally blank...
Page 190: ...Using M se 162 This page intentionally blank...
Page 226: ...Using the TouchPro CTG Monitor 198 This page intentionally blank...
Page 266: ...Using Lucina 238 This page intentionally blank...
Page 298: ...Care and Maintenance 270 This page intentionally blank...
Page 389: ......