Configuring the Mannequin
53
11. Gather the boggy/contracted uterus external genitalia fully inside the
mannequin’s torso and push the skin through the birth canal.
The Boggy/Contracted Uterus with External Genitalia
12. Tuck in the labia and position the uterus genitalia smoothly over the
standard birth canal.
13. Tuck the edge skin of the uterus under the torso skin around the genitalia
opening.
14. Push the external genitalia flap under the buttocks and attach it to the
rectal plug.
NOTE:
CAE Healthcare recommends placing the mannequin in McRoberts
position to perform this procedure.
15. Install the Backplate without the Cervix Retention Plate.
NOTE:
Ensure the arrows on the top of the plate point towards the
mannequin’s feet.
The external
genitalia