background image

Du line

®

Fieldbus

Installationbus

Specifications are subject to change without notice (12.12.2008)

1

Dupline®

®

is a registered trademark. A product of the CARLO GAVAZZI Group

Supply

Ordering no.

Internal battery

GP 7380 0080

Product Description

Ordering Key

Type: Dupline

®

Type no.
Supply

Carpark

Type GP 7380 0080

• Portable Configuration and Test Unit
• Configures the Carpark sensors GP622022xx
• Configures the Carpark monitor GP34829091
• Monitors the status of Dupline

®

addresses

• LCD-display
• 12-key tactile keyboard
• Supplied by standard 9V battery
• Multi calibration of the Carpark sensors
• Possibility of simulating sensors

Configuration and Test/ Sim-
ulations Unit for Carpark.
The configurator configures
the

Carpark

Sensors

GP622022xx and monitor
units GP34829091.
Monitors the Dupline

®

bus in

GTU mode and are able to

simulate the precense of
sensors.
Highly

recommended

for

Carpark configuration, trou-
bleshoothing and mainte-
nance

Type Selection

Power supply

9V battery (not included)

Type

6LR61

Battery Life Time (Sleep)

Typ. 2 years

Supply Specifications

Configuration and Test Unit

Display

2 x 16 characters

Type

LCD

Height of dots

5 mm

Keyboard

Tactile keys

No. of keys

12

Channel keys

1-8

Command keys

«

» «

» (scroll up/down)

« NO », « YES », « READ/ON »

Note:

Command key 0/9

performs the function as
mode/Enter in GTU mode.

Cable 1

GP73800080 to sensor or
monitor

GP73800080 connector

1 6/6 modular plug

Monitor or sensor

1 6/6 modular plug

Programmer cable

GAP-CAB

Cable 2

GP73800080 to Dupline

®

GP73800080 connector

3 mm jack socket

Dupline® Bus

GRIP

Test cable

GTU8-GRIB-CAB

Product Specifications

General Specifications

Environment

Degree of protection

IP 40

Pollution degree

3 (IEC 60664)

Operating temperature

0° to +50°C (+32° to +122°F)

Storage temperature

-20° to +60°C (-4° to +140°F)

Humidity

(non-condensing)

20 to 80%

Mechanical resistance

Shock

15 G (11 ms)

Vibration

2 G (6 to 55 Hz)

Dimensions

(l x w x d)

145 x 90 x 28 mm

Material

ABS, grey

Weight

250 g excluding battery

GP 7380 0080 709

Summary of Contents for Carpark GP 7380 0080

Page 1: ...configuration trou bleshoothing and mainte nance Type Selection Power supply 9V battery not included Type 6LR61 Battery Life Time Sleep Typ 2 years Supply Specifications Configuration and Test Unit Display 2 x 16 characters Type LCD Height of dots 5 mm Keyboard Tactile keys No of keys 12 Channel keys 1 8 Command keys scroll up down NO YES READ ON Note Command key 0 9 performs the function as mode ...

Page 2: ...ig urator will start reading the connected unit Reading Configuration is shown in the display while reading is in progress If a Carpark sensor is connected the user can in Mode selection select between Normal mode or Lane mode Configuration of a sensor Fig 2 Normal mode Standard sensor mode detects the presence of a Car in the parking space and light the red LED and sends a signal out on the L1 bu...

Page 3: ... counts up the total numbers of free spaces The Input and the Out put sensor are specified with their Dupline channels If for some reason there is a mismatch with the correct number of free parking places then it is possible to reset the counter when the roof is empty Fig 13 Roof Spaces in Slave mode Fig 12 In Out channels and Reset channels in Slave mode Fig 13 Master mode The GP3482 9091 724 mon...

Page 4: ...al 1 group Once connected to the Dupline the display shows the status of channel group A Active channels are indicated by their numbers Pressing 1 2 8 will activate the corresponding Dupline channel in the selected chan nel group Pressing or changes the channel group showing the display Digital 2 groups When the mode Digital 2 groups is selected the user may select an addi tional channel group for...

Page 5: ...bration is finished the fol lowing will be shown in the display FINISHED PRESS Mode Enter TO EXIT Pressing the Mode Enter button is the only way to restart calibration or entering a new mode of operation Warning Do not plug in the Jack connector when it is connected to Dupline and the configuration unit is ON This will cause a short circuit of the two wires Note If the Dupline carrier is missing t...

Reviews: