Müse Parameter Descriptions
301
Systemic Arteries Compliance Factor
The
Systemic Arteries Compliance Factor
parameter adjusts the pulse pressure (difference between
systolic and diastolic pressures) of the simulated patient’s systemic blood pressure. Increases in the
compliance factor result in a decreased (narrower) pulse pressure, while smaller values increase the
pulse pressure. Additionally, when the pulse pressure increases as a result of a reduced compliance
factor, both systolic and diastolic pressures increase. Conversely, with a narrower pulse pressure (higher
compliance factor), both the systolic and diastolic blood pressures also drop.
Default
: 1
Range
: 0.50 - 5.00
Pulmonary Arteries Compliance Factor
The
Pulmonary Arteries Compliance Factor
parameter adjusts the pulse pressure (difference
between systolic and diastolic pressures) of the simulated patient’s pulmonary blood pressure.
Increases in the compliance factor decrease (narrow) the pulse pressure, while smaller values increase
the pulse pressure. Additionally, when the pulse pressure increases as a result of a reduced compliance
factor, both systolic and diastolic pulmonary pressures increase. Conversely, with a narrower pulse
pressure (higher compliance factor) both the systolic and diastolic pulmonary pressures also drop.
Default
: 1
Range
: 0.20 - 5.00
Pulmonary Vasculature Resistance Factor
The
Pulmonary Vasculature Resistance Factor
parameter adjusts the baseline pulmonary vascular
resistance. Raising the value increases the pulmonary vascular resistance, while lowering the value
decreases the vascular resistance.
Raising the parameter value is analogous to increasing the resistance to blood flow through the
pulmonary vasculature. Under such conditions, the pulmonary artery pressure (PAP) and central
venous pressure (CVP) increase due to back-pressure through the right side of the heart.
Default
: 1
Range
: 0.10 - 10.00
Summary of Contents for Fidelis Lucina
Page 1: ...User Guide Maternal Fetal Simulator...
Page 2: ...2015 CAE Healthcare 905K470052 v2 1...
Page 28: ...Table Of Contents xxvi This page intentionally blank...
Page 36: ...Equipment Overview 8 This page intentionally blank...
Page 190: ...Using M se 162 This page intentionally blank...
Page 226: ...Using the TouchPro CTG Monitor 198 This page intentionally blank...
Page 266: ...Using Lucina 238 This page intentionally blank...
Page 298: ...Care and Maintenance 270 This page intentionally blank...
Page 389: ......