Syst em Events
18-3
Event Generation
As soon as a message-generating event occurs, a Call Request is automatically sent to
the
Alarm Output ID
. (The event is stored in the originating node's buffer until the event
connection is activated.) All events are transmitted in raw data format to the collecting
node, which constructs event messages and sends them to the display device(s).
An internal timer limits the time events are kept in the system buffer if the system fails
to bring the event connection up. If the timer expires, the buffer is cleared. The event
connection remains active until the event system detects that there are no events
occurring during the time period set for the
Line Idle Timer
. After the event connection
is cleared, the event system will repeat the above procedures if any events occur.
Displaying Events
To display any local events on the screen as they occur, press
[D]
at the Main Menu.
Event messages will continue to be sent to any destinations specified by the param-
eters described earlier in this chapter.
While this feature is activated, you cannot perform other operations on the
screen. Also, if the Primary Alarm Output device is unreachable, no local
events will be displayed.
A display at a collecting node looks like the example shown below. (A display at a
sending node will show only that node's events.)
Chicago
1008
06/16/1997
08:34:31
end of ipl
Chicago
1013
06/16/1997
08:34:32
L:2 P:2 link PAD fail
Chicago
1004
06/16/1997
08:34:38
L:2 P:0 link X.25 fail
Chicago
1005
06/16/1997
08:34:44
L:2 P:0 restart with cc=7 dc=0
Chicago
1006
06/16/1997
08:35:15
L:2 P:0 operational
St Louis
1008
06/16/1997
08:30:43
end of ipl
St Louis
1004
06/16/1997
08:30:50
L1 P:1 link X.25 fail
St Louis
450
06/16/1997
08:31:41
St Louis
1005
06/16/1997
08:32:24
L:1 P:3 restart with cc=0 dc=0
St Louis
1006
06/16/1997
08:32:35
L1 P:3 operational
St Louis
450
06/16/1997
08:33:01
St Louis
1005
06/16/1997
08:33:14
L:1 P:1 restart with cc=0 dc=0
St Louis
1008
06/16/1997
08:33:31
end of ipl
Press
[F3]
to stop displaying events and return to normal menu operations.
Summary of Contents for MMAC-Plus 9F116-01
Page 2: ......
Page 15: ...Section I Introduction ...
Page 16: ......
Page 37: ...Section II Configuration ...
Page 38: ......
Page 46: ......
Page 76: ...4 18 FRX FRM 3 3 User Guide Rev 04 ...
Page 174: ......
Page 196: ......
Page 271: ...Section III Operation ...
Page 272: ......
Page 340: ...17 46 FRX FRM 3 3 User Guide Rev 04 ...
Page 370: ......
Page 371: ...Section IV Appendices ...
Page 372: ......
Page 383: ...Appendix D Cause and Diagnostic Codes ...
Page 394: ......
Page 398: ......
Page 402: ...G 4 FRX FRM 3 3 User Guide Rev 04 ...