St atus and Statistics Displays
17-39
WD Req Pkts Rcv
is the number of "watchdog," or "keep-alive," requests received
from other servers. These are issued periodically to all clients, to
determine whether each client is still available.
WD Resp Pkts Rcv
is the number of received responses to keep-alive messages
issued by the local server.
Serial Pkts Rcv
is the number of NetWare file server serialization security frames
received. These broadcast frames are used by Novell to hold
information regarding the licensing of the file server executables.
Pkts Tx
is the total number of RIP and SAP packets transmitted on the
local interface.
Tx Completions
is the total number of successfully transmitted RIP and SAP
packets that originated at the local node.
Pkts Rcv
is the total number of RIP and SAP packets received on the local
interface.
Tx Pkts Filtered
is the number of packets denied transmission because of a filter
configured on the interface.
Rcv Pkts Filtered
is the number of packets denied reception because of a filter con-
figured on the interface.
Pkts Forwarded
is self-explanatory.
Echo Requests Rcv
is the number of Echo Requests received on the interface.
Echo Replies Rcv
is the number of replies to Echo Requests received on the
interface.
Err_Type Pkts Rcv
is the number of Novell error packets received on the interface.
Pkts Discarded
is the number of packets discarded because the interface was
down.
Pkts_2_Large Rcv
is the number of packets received that exceeded the Maximum
Transmission Units configured for the interface. These packets
are discarded.
Major/Minor Version
are the version numbers of the IPX stack.
Rcv Header Error
is the number of IPX packets received with incorrect header
information. The header should be 30 bytes and contain network,
node, and socket addresses for source and destination.
Ukn Sockets Rcv
is the number of socket numbers received that could not be iden-
tified. Some socket numbers (assigned by Novell) are:
0451
= NCP Process
0452
= SAP Process
0453
= RIP Process
0455
= NetBIOS Process
0456
= Diagnostics Process
Rcv BSys Discard
are not monitored by the FRX/FRM, but are included in the
through
statistics list because it is part of the IPX MIB. The statistics in
R_Decomp Errors
the list between the above two are:
Bad Checksum Rcv, Local Rcv
Pkts, Path_Not Found, Local Tx Pkts, Bad Local Tx Pkts, Tx BSys
Discard, Open Socket Fail, State Changes, Init Fail, Ms to Tx 1 Byte
R-RIP Ent-Filter
is the number of received RIP entries discarded due to a filter.
T-RIP Ent-Filter
is the number of transmitted RIP entries discarded due to a filter.
Summary of Contents for MMAC-Plus 9F116-01
Page 2: ......
Page 15: ...Section I Introduction ...
Page 16: ......
Page 37: ...Section II Configuration ...
Page 38: ......
Page 46: ......
Page 76: ...4 18 FRX FRM 3 3 User Guide Rev 04 ...
Page 174: ......
Page 196: ......
Page 271: ...Section III Operation ...
Page 272: ......
Page 340: ...17 46 FRX FRM 3 3 User Guide Rev 04 ...
Page 370: ......
Page 371: ...Section IV Appendices ...
Page 372: ......
Page 383: ...Appendix D Cause and Diagnostic Codes ...
Page 394: ......
Page 398: ......
Page 402: ...G 4 FRX FRM 3 3 User Guide Rev 04 ...