Introduction to Syst em Operation
15-3
still active connections on the port).
H
Unquiesce a Range of Ports
– Unquiesces a specified group of same-type
ports.
C On-Line Database Operations
– (Chapter 16) backs up database and/or system
files locally or remotely.
A Back up the Current Database to a Remote FRX6000
– copies the database
from an FRX4000 or FRX6000 onto a diskette at a remote FRX6000.
B Restore the Backed-Up Database to a Remote FRX6000
– copies the
database backed up by the above operation to the hard disk at the remote
FRX6000.
C Restore the Backed-Up Database to a Remote FRX4000
D Back up the Current Database to a Local Directory
E Restore the Database from a Local Directory
F
Back Up the Current System Files to a Local Directory
G Restore the System Files from a Local Directory
D Test X.25 Address Translation Templates
– (Chapter 7) Tests templates to
assure they were correctly created.
E Re-Load Initialization to Async Console
– (Chapter 16) Sends default terminal
settings to an Auxiliary Console on the node's Console port (FRX4000) or
COM1 port (FRX6000 or FRM).
F
IP Ping Connectivity Test
– (Chapter 16) Uses the Ping function to determine
whether an IP host is reachable.
G On-Line SDLC PU Operations
(Chapter 8)
A
Disable an SDLC PU
– Takes any SDLC PU in the node off line.
B
Disable a Range of SDLC PUs
– Takes a group of PUs off line.
C
Enable an SDLC PU
– Brings any SDLC in the node on line.
D
Enable a Range of SDLC PUs
– Brings a group of PUs on line.
H NetView Access
– (Appendix E) allows a NetView manager to obtain
information on the node via NMVT commands or from files in the node
database.
I
CSU/DSU Tests
– (Chapter 16)
A
Self Test
– transmits a test pattern to the analog portion of the circuitry and
loop the pattern back to itself.
B
Pattern Generation Test
– transmits a PRBS (pseudo-random bit sequence)
test pattern to the remote device, which will loop the signals back.
J
Frame Relay Backup Operations
– (Chapter 16) allows manual switching from
a primary frame relay DLCI to its backup, or from the backup to the primary,
without configuring a backup group in the database.
A
Initiate Switching Primary DLCI Over to its Backup
B
Initiate Switching DLCI Back to the Primary
C
Status Displays
(Chapter 17)
A Node Status
– displays performance and link status for the node.
B Port Status
– displays port type, operational status, and link states for all ports
on the node.
C Virtual Connections
– displays DLCIs/LCNs, link states, subscribers, and
(frame relay only) performance for all logical connections.
D Port Signals
– displays configuration data for each port on a specified LP
(FRX6000) or in the node (FRX4000, FRM), and shows on/off status of
each signal at the interface.
E Line Monitor
– displays control and information data of all level-3 packets
passing through a specified X.25 port.
F
Protocol Status
A
IPX RIP Table Display
– displays the contents of the RIP table.
B
IPX SAP Table Display
– displays the contents of the SAP table.
Summary of Contents for MMAC-Plus 9F116-01
Page 2: ......
Page 15: ...Section I Introduction ...
Page 16: ......
Page 37: ...Section II Configuration ...
Page 38: ......
Page 46: ......
Page 76: ...4 18 FRX FRM 3 3 User Guide Rev 04 ...
Page 174: ......
Page 196: ......
Page 271: ...Section III Operation ...
Page 272: ......
Page 340: ...17 46 FRX FRM 3 3 User Guide Rev 04 ...
Page 370: ......
Page 371: ...Section IV Appendices ...
Page 372: ......
Page 383: ...Appendix D Cause and Diagnostic Codes ...
Page 394: ......
Page 398: ......
Page 402: ...G 4 FRX FRM 3 3 User Guide Rev 04 ...