13-10
FRX/FRM 3. 3 User G uide, Rev 04
Configuring Bridge Filter Applications
Bridge Filter Applications determine how filters will be used at the interface. To
review existing applications, press
[H]
at the Filter Definitions and Applications Con-
figuration Menu (or
[A], [A], [E], [F], [H]
from the Main Menu). To configure an appli-
cation, press
[I]
at the Filter Definitions and Applications Configuration Menu. When
prompted, enter:
●
Bridge Port Number
:
0–95
. (The default is
0
.) (This number simply identifies the
interface.)
●
Filter Type
:
4
= Generic
5
= MAC (Default)
6
= LLC2 SAP
7
= Protocol
8
= Bridged native NetBIOS.
A MAC filter will be applied to incoming frames whether or not
bridging is enabled (in Bridge Node Defaults). Other filter types will
be applied only if bridging is enabled.
●
Direction
:
i
(inbound) or
o
(outbound). (The default is
o
.)
●
Any other requested information, referring to Table 13-7 (on page 13-11).
Figure 13-3 Typical Bridge Filter Applications Record
[A],[A],[E],[F],[I]
from Main Menu
Up to 100 filters can be configured, displayed over ten "pages" (screens).
[PgDn]
and
[PgUp]
can be used to move through the screens. (At any screen, pressing
[F3]
will save
the configuration for all ten screens and exit the display. Pressing
[Esc]
at any screen
will abandon the changes for all ten screens and exit.)
When finished configuring filter definitions and applications, you must perform an
on-line update to make the changes effective immediately. Press
[J]
at the Filter Def-
initions and Applications Configuration Menu. The changes will be sent to the
software running on the RLPs.
N ode N ame= node_xyz
Bridge Filter A pplications
*
Brid ge Port Numb er
2
*
Filter Type
5 MA C
*
Direction
I –Inb ound
A Permit
Y
B Filter App lication 1
0
C Filter App lication 2
0
D Filter App lication 3
0
E Filter App lication 4
0
F Filter App lication 5
0
G Filter App lication 6
0
H Filter App lication 7
0
I
Filter App lication 8
0
J
Filter App lication 9
0
K Filter App lication 10
0
Op tion :
Summary of Contents for MMAC-Plus 9F116-01
Page 2: ......
Page 15: ...Section I Introduction ...
Page 16: ......
Page 37: ...Section II Configuration ...
Page 38: ......
Page 46: ......
Page 76: ...4 18 FRX FRM 3 3 User Guide Rev 04 ...
Page 174: ......
Page 196: ......
Page 271: ...Section III Operation ...
Page 272: ......
Page 340: ...17 46 FRX FRM 3 3 User Guide Rev 04 ...
Page 370: ......
Page 371: ...Section IV Appendices ...
Page 372: ......
Page 383: ...Appendix D Cause and Diagnostic Codes ...
Page 394: ......
Page 398: ......
Page 402: ...G 4 FRX FRM 3 3 User Guide Rev 04 ...