18-2
FRX/FRM 3. 3 User G uide, Rev 04
The following shows an example of a two-node event routing configuration.
Figure 18-1 Event Reporting Configuration Example
Alarm Buffer
Each node has a buffer where events are stored while waiting for transmission. When
a buffer reaches the percentage of full capacity specified by the parameter
Max Con-
gestion
, further events originating at that node are lost until the percentage of capacity
specified by the parameter
Min Congestion
is reached.
When the buffer reaches
Max Congestion
, the node adds the event message
Beginning
of congestion
to the buffer. No more events are put into the buffer until it has reached
Min Congestion
, at which time another message,
End of congestion, “n” events lost
, is
put into the buffer, and all events are again put into the buffer.
When the collecting node's event buffer reaches
Max Congestion
, events are held in the
originating nodes' buffers until the buffers reach
Max Congestion
or the collecting
node begins accepting events again.
Collecting Node ID =
222
Primary Alarm Output ID =
12345
Secondary Alarm Output ID =
C1
Network Mgmt.
Station with
Address
12345
Printer
Node 1
Collecting Node
Optional
Monitor
COM1
Alarms from
Node 2
Node 2
Optional
Async
Terminal
Summary of Contents for MMAC-Plus 9F116-01
Page 2: ......
Page 15: ...Section I Introduction ...
Page 16: ......
Page 37: ...Section II Configuration ...
Page 38: ......
Page 46: ......
Page 76: ...4 18 FRX FRM 3 3 User Guide Rev 04 ...
Page 174: ......
Page 196: ......
Page 271: ...Section III Operation ...
Page 272: ......
Page 340: ...17 46 FRX FRM 3 3 User Guide Rev 04 ...
Page 370: ......
Page 371: ...Section IV Appendices ...
Page 372: ......
Page 383: ...Appendix D Cause and Diagnostic Codes ...
Page 394: ......
Page 398: ......
Page 402: ...G 4 FRX FRM 3 3 User Guide Rev 04 ...