On-line Operat ions
16-17
FRX4000 CSU/DSU Tests
To test the CSU/DSU port on an FRX4000, the port must first be disabled. If nec-
essary, press
[A]
at the Operations Menu (or
[B], [A]
from the Main Menu) to disable
the port.
To run a CSU/DSU test, press
[I]
at the Operations Menu, then press the letter corre-
sponding to the desired test:
[A]
=
Self Test
– transmits a test pattern to the analog portion of the circuitry and
loop the pattern back to itself.
[B]
=
Pattern Generation Test
– transmits a PRBS (pseudo-random bit sequence)
test pattern to the remote device, which will loop the signals back.