St atus and Statistics Displays
17-5
Displaying Virtual Connections
To display all physical and logical connections on a physical port, press
[C]
at the
Status Displays Menu and, when prompted, enter the LP and physical port numbers.
The display will differ depending on whether or not the port is a frame relay port.
Figure 17-3 shows a frame relay port and Figure 17-4 shows a non-frame relay port.
Figure 17-3 Virtual Connections Display on Frame Relay Port
[C],[C]
from Main Menu
Information in this Display
Seq
is a sequence number used to identify the connection.
DLCI
is the DLCI on which the connection exists.
State
:
Data_trans
means that call processing was successful and the connection
is in the data transmission state.
Call_setup
means that the attached device is waiting for Call Accept.
Clearing
means that the attached device is in Call Clear state, waiting for
Clear Confirmation.
Resetting
means that a Reset has been sent to the remote device, and the
attached device is waiting for a Reset Confirmation.
Port_down
is self-explanatory.
Connected
means that a connection has been established.
Not_conect
means that a connection has not been established or has been
broken.
Node N ame= node_xyz
Conn ection S tatus Disp lay Menu (Page 1)
LP: 0
Port: 0
From:
C u m u l a t i v e
To:
SeqDLC I
S tate
Tran s
R ecd
D is c
LP
P
DLCI State
1
16
D ata_tran s
587
497
0
1
9
16
Data_trans
2
17
D ata_tran s
588
574 0
1 10
17
Data_trans
3
18
D ata_tran s
592
586 1
1 11
18
Data_trans
4
20
D ata_tran s
580
486 0
1 14
20
Data_trans
5
32
D ata_tran s
585
602 6
1 18
28
Data_trans
6
33
D ata_tran s
600
594 0
1 19
29
Data_trans
7
34
D ata_tran s
621
600 0
1 22
30
Data_trans
8
35
D ata_tran s
579
543 0
1 23
31
Data_trans
9
36
D ata_tran s
586
584 0
1 24
32
Data_trans
10 25
D ata_tran s
588
586 4
1 30
25
Data_trans
11 24
D ata_tran s
593
610
0
1
29
24
Data_trans
12 42
D ata_tran s
602
498
5
1
33
42
Data_trans
13 43
D ata_tran s
610
506
0
1
34
43
Data_trans
14 44
D ata_tran s
585
560
0
1
35
44
Data_trans
Summary of Contents for MMAC-Plus 9F116-01
Page 2: ......
Page 15: ...Section I Introduction ...
Page 16: ......
Page 37: ...Section II Configuration ...
Page 38: ......
Page 46: ......
Page 76: ...4 18 FRX FRM 3 3 User Guide Rev 04 ...
Page 174: ......
Page 196: ......
Page 271: ...Section III Operation ...
Page 272: ......
Page 340: ...17 46 FRX FRM 3 3 User Guide Rev 04 ...
Page 370: ......
Page 371: ...Section IV Appendices ...
Page 372: ......
Page 383: ...Appendix D Cause and Diagnostic Codes ...
Page 394: ......
Page 398: ......
Page 402: ...G 4 FRX FRM 3 3 User Guide Rev 04 ...