St atus and Statistics Displays
17-29
Configuring LP and Port Statistics Thresholds
For each LP and port statistic, you can specify a threshold that, when crossed, causes
an alarm to be sent to the collecting node.
Press
[A]
at the Statistics Menu. When prompted, enter:
●
Statistic level
:
L
for LP or
P
for Port.
●
LP
:
0
on FRX4000 or FRM,
0–7
on FRX6000.
●
Port
(if requested):
0–7
.
A menu like the following Port Statistics example will be displayed.
Figure 17-13 Port Statistics Configuration Menu
[E],[A]
from Main Menu
Changing a threshold changes the database value. Press
[F7]
to write the
change to system memory.
A threshold is either a number or a percentage, depending on the statistic. The valid
range for any statistic is
0–65535
(default =
0
). When the measured value for the sta-
tistic crosses the threshold (in either direction), an alarm is generated.
Nod e Name=n ode_xyz
Port S tatis tics (Thres holds)
LP: 0
Port: 1
Datab ase
Sys tem Memory
A Received frames/Sec (*10)
0
0
B Tran smitted frames/Sec (*10)
0
0
C Retran frames/Sec (*10)
0
0
D FC S errors /S ec (*10)
0
0
E Logical rejects/Sec (*10)
0
0
F Tran smit error ratio
0
0
G Receive error ratio
0
0
H % R eceive p ort utilization
0
0
I
% Trans mit port u tilization
0
0
Option:
Summary of Contents for MMAC-Plus 9F116-01
Page 2: ......
Page 15: ...Section I Introduction ...
Page 16: ......
Page 37: ...Section II Configuration ...
Page 38: ......
Page 46: ......
Page 76: ...4 18 FRX FRM 3 3 User Guide Rev 04 ...
Page 174: ......
Page 196: ......
Page 271: ...Section III Operation ...
Page 272: ......
Page 340: ...17 46 FRX FRM 3 3 User Guide Rev 04 ...
Page 370: ......
Page 371: ...Section IV Appendices ...
Page 372: ......
Page 383: ...Appendix D Cause and Diagnostic Codes ...
Page 394: ......
Page 398: ......
Page 402: ...G 4 FRX FRM 3 3 User Guide Rev 04 ...