Info and Error LEDs
This section explains the details of the event/error code that appears when an event occurs. If there is a
corresponding corrective action described below for the code, try it first. If the code is still displayed after trying the
corrective action, contact Buffalo technical support for assistance.
Errors
If an error occurs, the error LED will glow red. You can also confirm the current status from the Dashboard in Settings
or by using NAS Navigator2. If NAS Navigator2 displays the error as an unknown error, check the Dashboard in
Settings for the error details.
Code
Description
Corrective Action
E10
The TeraStation is running on the UPS
battery due to a power outage.
Shut down the TeraStation safely and wait
until the power outage ends. If certain
settings are configured, the TeraStation
may shut down automatically when the
error is detected.
If the setting to use the UPS connected to
this TeraStation has been configured, the
UPS cable may be disconnected.
Verify that the UPS cable or LAN cable is
connected properly.
If the setting to use the UPS connected to
another TeraStation on the same network
has been configured, the LAN cable of this
TeraStation may be disconnected.
E11
An error occurred in the fan speed.
Check that no foreign objects or dust are
clogging the fan. If any foreign objects or
dust are found, use a pair of tweezers, an
air duster, or other tools to remove them.
E12
A rise in the system temperature may have
exceeded the allowable safety value.
Move the TeraStation to a cool location. Do
not place objects in the area around the
TeraStation.
E14
The RAID array cannot be mounted.
If the message appears after initial bootup,
make sure drives are inserted properly
by referring to the
section in chapter 1. For all other cases,
run a drive check on the RAID array by
referring to the
section
in chapter 4.
E16
Unable to find the drive.
Re-insert the drive by referring to the
section in chapter 1.
E22
Unable to mount the drive.
Format the drive. After formatting, if the
error still appears after rebooting, replace
the drive.
E27
Unable to find the failover backup
TeraStation.
Reconfigure the failover backup
TeraStation for failover by referring to the
section in chapter 5.
E30
An error occurred, so the drive was
removed from the RAID array.
Replace the drive by referring to the drive
replacement sections in chapter 8.
Summary of Contents for TeraStation 3010
Page 29: ...28 Chapter 3 File Sharing 3 Click Create User...
Page 32: ...31 Chapter 3 File Sharing 3 Click Add Group...
Page 71: ...70 Chapter 4 Storage Management 6 Click Edit under NAS Volume 7 Click Create Volume...
Page 88: ...87 Chapter 5 Backup 4 Enter the backup device access key and click OK 5 Click Add...
Page 111: ...110 Chapter 5 Backup 3 Click Select Backup Disk 4 Select the shared folder then click Use Disk...
Page 113: ...112 Chapter 5 Backup 7 Time Machine will count down from 120 seconds then backup will begin...
Page 125: ...124 Chapter 6 Cloud Services and Remote Access 5 Click Edit...
Page 137: ...136 Chapter 6 Cloud Services and Remote Access 4 Click the Options tab 5 Click Edit...
Page 147: ...146 Chapter 6 Cloud Services and Remote Access 4 Click the Options tab...
Page 148: ...147 Chapter 6 Cloud Services and Remote Access 5 Click Edit...
Page 176: ...175 Chapter 7 Advanced Features 11Click the NFS Rules tab 12Click Add...
Page 205: ...204 Chapter 7 Advanced Features 3 Click FQDN Mapping 4 Click Add...