User's Manual
804
Document #: LTRT-89729
Mediant 3000
Parameter
Description
Typically, this feature is used only when early media (enabled using the
EnableEarlyMedia parameter) is used to establish the voice path before
the call is answered.
Notes:
To activate this feature, set the EnableDSPIPMDetectors parameter
to 1.
This feature is applicable only when the protocol type is CAS.
Web/EMS: Max Call
Duration (min)
[MaxCallDuration]
Defines the maximum duration (in minutes) of a call. If this duration is
reached, the device terminates the call. This feature is useful for
ensuring available resources for new calls, by ensuring calls are
properly terminated.
The valid range is 0 to 35,791. The default is 0 (i.e., no limitation).
[MinCallDuration]
Defines the minimum call duration (in seconds) for the Tel side. If an
established call is terminated by the IP side before this duration expires,
the device terminates the call with the IP side, but delays the
termination toward the Tel side until this timeout expires.
The valid value range is 0 to 10 seconds, where 0 (default) disables this
feature.
For example: assume the minimum call duration is set to 10 seconds
and an IP phone hangs up a call established with a BRI phone after 2
seconds. As the call duration is less than the minimum call duration, the
device does not disconnect the call on the Tel side. However, it sends a
SIP 200 OK immediately upon receipt of the BYE to disconnect from the
IP phone. The call is disconnected from the Tel side only when the call
duration is greater than or equal to the minimum call duration.
Notes:
This parameter is applicable to IP-to-Tel and Tel-to-IP calls.
This parameter is applicable only to ISDN and CAS protocols.
Web: Send Digit Pattern
on Connect
EMS: Connect Code
[TelConnectCode]
Defines a digit pattern to send to the Tel side after a SIP 200 OK is
received from the IP side. The digit pattern is a user-defined DTMF
sequence that is used to indicate an answer signal (e.g., for billing).
The valid range is 1 to 8 characters.
Note:
This parameter is applicable to CAS.
Web: Disconnect on
Broken Connection
EMS: Disconnect Calls
on Broken Connection
[DisconnectOnBroken
Connection]
Determines whether the device releases the call if RTP packets are not
received within a user-defined timeout.
[0]
No
[1]
Yes (default)
Notes:
The timeout is configured by the BrokenConnectionEventTimeout
parameter.
This feature is applicable only if the RTP session is used without
Silence Compression. If Silence Compression is enabled, the device
doesn't detect a broken RTP connection.
During a call, if the source IP address (from where the RTP packets
are received) is changed without notifying the device, the device
filters these RTP packets. To overcome this, set the
DisconnectOnBrokenConnection parameter to 0; the device doesn't
detect RTP packets arriving from the original source IP address and
switches (after 300 msec) to the RTP packets arriving from the new
source IP address.
This parameter can also be configured in an IP Profile.
Summary of Contents for Mediant 3000
Page 2: ......
Page 26: ...User s Manual 26 Document LTRT 89729 Mediant 3000 Reader s Note...
Page 27: ...Part I Getting Started with Initial Connectivity...
Page 28: ......
Page 40: ...User s Manual 40 Document LTRT 89729 Mediant 3000 Reader s Notes...
Page 41: ...Part II Management Tools...
Page 42: ......
Page 44: ...User s Manual 44 Document LTRT 89729 Mediant 3000 Reader s Notes...
Page 80: ...User s Manual 80 Document LTRT 89729 Mediant 3000 Reader s Notes...
Page 98: ...User s Manual 98 Document LTRT 89729 Mediant 3000 Reader s Notes...
Page 103: ...Part III General System Settings...
Page 104: ......
Page 113: ...Part IV General VoIP Configuration...
Page 114: ......
Page 144: ...User s Manual 144 Document LTRT 89729 Mediant 3000 Reader s Notes...
Page 164: ...User s Manual 164 Document LTRT 89729 Mediant 3000 Reader s Notes...
Page 222: ...User s Manual 222 Document LTRT 89729 Mediant 3000 Reader s Notes...
Page 224: ...User s Manual 224 Document LTRT 89729 Mediant 3000 Reader s Notes...
Page 275: ...Part V Gateway and IP to IP Application...
Page 276: ......
Page 278: ...User s Manual 278 Document LTRT 89729 Mediant 3000 Reader s Notes...
Page 399: ...Part VI Session Border Controller Application...
Page 400: ......
Page 402: ...User s Manual 402 Document LTRT 89729 Mediant 3000 Reader s Notes...
Page 464: ...User s Manual 464 Document LTRT 89729 Mediant 3000 Reader s Notes...
Page 465: ...Part VII Stand Alone Survivability Application...
Page 466: ......
Page 474: ...User s Manual 474 Document LTRT 89729 Mediant 3000 Reader s Notes...
Page 494: ...User s Manual 494 Document LTRT 89729 Mediant 3000 Reader s Notes...
Page 497: ...Part VIII IP Media Capabilities...
Page 498: ......
Page 501: ...Part IX High Availability System...
Page 502: ......
Page 515: ...Part X Maintenance...
Page 516: ......
Page 522: ...User s Manual 522 Document LTRT 89729 Mediant 3000 Reader s Notes...
Page 524: ...User s Manual 524 Document LTRT 89729 Mediant 3000 Reader s Notes...
Page 552: ...User s Manual 552 Document LTRT 89729 Mediant 3000 Reader s Notes...
Page 562: ...User s Manual 562 Document LTRT 89729 Mediant 3000 Reader s Notes...
Page 565: ...Part XI Status Performance Monitoring and Reporting...
Page 566: ......
Page 578: ...User s Manual 578 Document LTRT 89729 Mediant 3000 Reader s Notes...
Page 609: ...Part XII Diagnostics...
Page 610: ......
Page 624: ...User s Manual 624 Document LTRT 89729 Mediant 3000 Reader s Notes...
Page 626: ...User s Manual 626 Document LTRT 89729 Mediant 3000 Reader s Notes...
Page 638: ...User s Manual 638 Document LTRT 89729 Mediant 3000 Reader s Notes...
Page 639: ...Part XIII Appendix...
Page 640: ......
Page 864: ...User s Manual 864 Document LTRT 89729 Mediant 3000 Reader s Notes...
Page 871: ...Version 6 6 871 Mediant 3000 User s Manual 55 Selected Technical Specifications Reader s Notes...