TeleBoss 830 - Wireless Modem Advanced Settings
A) Idle Timeout (minutes) [0]
B) Keep-Alive Threshold (minutes) [0]
C) PPP Debug Enable [OFF]
D) Connectivity Check Settings [OFF]
Idle Timeout
Idle Timeout sets the number of minutes (0
– 255) to wait before disconnecting an inactive modem
connection. A setting of 0 means the connection will not be terminated. The default setting is 0 minutes.
Keep-Alive Threshold (minutes)
This option sets the length of time, in minutes, after which the wireless modem will send an outbound
packet to maintain a connection, if no data has been transmitted. A setting of 0 disables this feature. The
default is 0.
PPP Debug Enable
This is an ON/OFF toggle to enable capturing PPP traffic to a log file which can be extracted from the device
and used for debugging purposes. The default setting is OFF.
Connectivity Check Settings
This option brings up a menu to set up the unit to check wireless connectivity. The TeleBoss can be
configured to ping up to two user-specified IP addresses at a user-specified interval. If the count of
consecutive failed tests reaches a user-specified threshold, and the modem is not in use, the TeleBoss will
power cycle the wireless modem. If the situation persists the TeleBoss will power cycle.
The modem will not power cycle more often than every 10 minutes. This interval increases on consecutive
triggers to a maximum interval of 1 hour. If resetting the modem does not restore connectivity, then the
TeleBoss will be power cycled on the next trigger. The TeleBoss will not power cycle more often than every 12
hours. A system message is displayed in any open command processor saying that the system is going to
reboot in 30 seconds.
TeleBoss 830 - Connectivity Check Settings
A) Enable [OFF]
B) IP Address 1 [0.0.0.0]
C) IP Address 2 [0.0.0.0]
D) IP Address 3 [0.0.0.0]
E) Check Interval (minutes) [2]
F) Fail Threshold [5]
G) RX Reset [ON]
Enable
This is an ON/OFF toggle to enable or disable the feature. Default is OFF.
IP Address n
Use these fields to set the IP address(es) that will be pinged for the connectivity check. The default is 0.0.0.0,
note the unit will not ping 0.0.0.0.
Check Interval (minutes)
This field is used to set how often the IP address(es) will be pinged, in minutes. Range is 1 to 10 minutes. The
default is 2.