TeleBoss 830 2.11.370 STD User Manual
Page 6
Installation Sequence
1. Physically install the TeleBoss into your site. Use the included Mounting Brackets to secure to a standardly
grounded equipment rack.
2. If the unit is not mounted within a grounded rack system, connect the attached ground wire securely to an
appropriate earth ground.
3. If a wireless modem is installed, attach the antenna to the SMA connector.
4. Connect your Asentria unit to power and power it up. See the
instructions and safety warnings.
Note:
Proceed with connecting other equipment only after confirming that the unit has powered up
normally per the
5. Connect an Ethernet cable into the RJ45 jack labeled ETH1.
6. If connecting to the TeleBoss using a serial cable, see the
Access via a Serial Connection
connection instructions.
7. If a POTs modem is installed, attach an RJ11 phone wire to the MODEM port.
8. Connect any EventSensors using the RJ45 Sensor port. See the
EventSensor Installation Connections
chapter for additional instructions.
9. Install any IO connections based on your site requirements.
Power Requirements & Options
The TeleBoss can be configured with one or two options for incoming power.
The standard power option is the 15VDC power jack in the back of the unit. The supplied power jack
connects via an AC power adaptor to a standard wall power plug.
There is an optional 24VDC or -48VDC power option which is supported on a DC power card installed in the
rear panel of the unit. If using a DC power source, the unit is configured with a 4-pin Phoenix style connector
for use with a DC power source.
The unit is shipped with the instructions for direct connection to a DC power
source. The instructions are shown below, in case they are missing from the box:
Standard 15VDC via AC Power
If you are using a standard AC wall plug,
the unit uses a barrel connector for connecting to the 15VDC power
adapter. The 15VDC power adapter then connects to a standard AC wall plug. Asentria has options for a US,
UK, European, Australian or Japanese AC power plug type. This power option ships with the unit unless a
DC power option is ordered.
Battery Backup Module
A TeleBoss can be ordered with an optional battery backup module.
There are two options that can be used to power a unit after AC power is
lost. The Lead acid battery module is indicated with /BB in the product
number. A lithium battery backup option is indicated with a /BB2.
Once a unit with a battery backup module is installed and powered up on
AC Power, simply move the slide switch to “Enable” to enable the run
time battery backup feature.