TeleBoss 830 - Serial Settings
A) 1-I/O 1 Settings
B) 2-I/O 2 Settings
Note:
Because I/O2 has all the settings the other serial ports have, plus a few more, it will be described in
the section below with differences in other ports mentioned when necessary.
TeleBoss 830 - Serial 2
A) Target Name [I/O 2]
B) Baud Rate [19200]
C) Data Format [8N1]
D) Handshaking [NONE]
E) Wrap Around [OFF]
F) Record Stamping
G) Character Masking [ON]
H) Data Alarm Enable [OFF]
I) Store Data To [2]
J) Store Alarms During Pass-Through [OFF]
K) Duplex [FULL]
L) Inactivity Timeout [0]
M) Port Mode [COMMAND]
N) Inline Mode Handshaking [XON/XOFF]
O) Strip Sent Pass-Through LFs [OFF]
P) Strip Received Pass-Through LFs [OFF]
Q) Disable Serial Setup via DIP Switch [OFF]
R) Data Type [ASCII]
S) Change ETX to CR/LF [OFF]
Target Name
Set the name given to the device connected to the other end of each port. This field will accept up to 24
alphanumeric characters. The target name is used in event notifications. The default setting is I/O
n
.
Baud Rate
The Baud Rate option displays a selection menu for baud rates available for the port. These values range
from 300 baud to 115200 baud. The default setting is 19200.
Data Format
The Data Format toggles settings for word length, parity, and stop bit settings. The available options are:
8N1, 7E1, 7O1, 7N1, 8O2 and 8N2. The default setting is 8N1.
Handshaking
Handshaking toggles settings for how the port will handshake with the connected device. The available
options are: NONE, XON/XOFF, BOTH, and DTR. The default setting is NONE.
Wrap Around
Wrap Around is an ON/OFF toggle to set whether the incoming data will wrap (overwrite) the oldest data in
the file should it become full. The default setting is OFF.
Record Stamping
This option displays a menu that allows you to select whether the Date/Time and/or the Site Name are pre-
pended to each incoming data string. The default setting for Date/Time Stamping and Site Name Stamping is
OFF.