LON Devices
(COMMUNICATION MENU, 5,
)
LON DEVICES SETUP Add Rem Srv All CLr
Node :
1 Stat: en
FldSeq. :
0
Type :
FBP700
FldType :
None
ID :
001 Ver:1.02
FldID :
000 Ver: 0.00
NID :
00A008781900
FldNID :
000000000000
LOC :
00/00/00
0. . 9,
^V,
<>,
E,
X
Alarms: 0
Faults: 1
Cond.: 0
P: 1
SDZ
Return to Communication Menu
Page 37
Select field to be changed
Enter number 0..9 or
to change node field
Select mode
Confirm entry (Unlock memory!)
Any FP700 module or FBP700, up to an amount of 32, can be connected to a LON port
of the FP2000. Each of these modules or repeaters can be uniquely identified by means
of the node ID. To start configuring a module connected to the LON port, the service
switch, which every FP/FBP700 device has, needs to be pressed. Every model has an
unique Neuron ID that is transmitted to the firepanel when the service switch is pressed.
This Neuron ID is stored in the volatile memory and is displayed in the FldNID field. In
the FldType the type of device is displayed e.g. FBP700, the FldID displays the ID
assigned to it in the sequence the service switches were pressed. The “FldNID” is
highlighted if it corresponds with the ID of the last pressed module. The Ver. displays the
version of software in the connected device. By using the
,
&
keys the
function required can be selected. If Add is selected the information on the right-hand
side of the screen is transferred to the left-hand side and the data is transferred form the
volatile memory to the selected non-volatile memory. If Rem (remove) is selected the
data of the selected device is removed from the non-volatile memory. When Srv (service)
is selected, the service led of the device selected previously is lit. When All is selected all
devices, where previously the service switches have been pressed will be added to the
non-volatile memory and if CLr (Clear) is selected all volatile data is cleared.
“NID” is highlighted if it corresponds with the ID of the last pressed module.
The status of a device connected to any of the 32 nodes can be set to either en - enable
or dis - disable. If a node is set to disable and a module were assigned to that node
previously; the panel will indicate a fault.
The following types of devices can be connected the LON port (Currently only the
FBP700 is included):
FC700:
FP700 Front CPU card
FCD700:
FP700 Front CPU card with display
SD700:
FP700 Sounder card
ZI700:
FP700 Zone Indicating Module
PS700:
FP700 Power Supply
SIB716:
FP700 Supervised Input board
OCB724:
FP700 Open Collector board
SOB708:
FP700 Supervised Output board
FM700:
Fireman’s Panel
FBP700:
Repeater Panel
FBP700-01: Dutch Repeater Panel