Alarms
The first two alarms indicate major problems, and should remain clear when
running with a good connection. The other alarms may light during processing,
and indicate various physical events:
Alarm
Lights when this event occurs:
Loss of Signal
Total loss of signal; most likely a cabling problem (lost connection,
damaged cable, etc.).
Signal Label
Mismatch
The analysis device can’t figure out the incoming signal; specifically, the
received value in the C2 octet doesn’t equal hex 13 for seven consecutive
frames. The most likely problem is a device that’s connected to an ATM
device through the wrong type of physical connection (e.g., an OC-
12c/STM-4c device cabled to an OC-3 device).
Loss Of Pointer
Loss of Pointer error; i.e., there’s no valid H1/H2 pointer in the
STS-12c/STM-4c frame.
Out Of Frame
Out of Frame error; i.e., the analysis device observes four consecutive in-
error A1/A2 framing patterns. The pattern observed consists of the third
A1 octet and the first A2 octet.
Loss Of Frame
Loss of Frame error; i.e., the STS-OOF is active for 24 consecutive
STS-12c/STM-4c frames.
Loss Of Cell
Delineation
Loss of Cell Delineation error (indicating a loss of cell synchronization).
Lights when seven consecutive HEC errors occur at the current cell-
delineation position.
Summary BIP Error
Bit-Interleaved Parity check error; i.e., an error in the B1, B2, or B3 BIP-8
or BIP-24 codes at the receiver.
Line AIS
Alarm Indication Signal on the line (signal is sent downstream to report an
error detected upstream). Lights after the three least significant bits of the
K2 octet are ‘111’ for five consecutive frames.
(MS-AIS = equivalent SDH term)
Line RDI
RDI (Remote Defect Indicator) error on the line (signal is sent upstream to
report a receive or transmission error downstream — generally a frame-
sync error or a loss of incoming signal). Lights when the three least
significant bits of the K2 octet are ‘110’ for five consecutive frames.
(MS-RDI = equivalent SDH term)
Path AIS
Alarm Indication Signal on the path; i.e., the H1 and H2 octets are all ones
for three consecutive frames.
(AIS = equivalent SDH term)
Path RDI
RDI (Remote Defect Indicator) error on the path, indicating a loss of cell
delineation. Lights when the analysis device detects a value of 9 in the
most significant nibble of the G1 octet of the STS-12c/STM-4c overhead.
(RDI = equivalent SDH term)
Path FEBE
Far End Block Error on the path, indicating that the block (frame) has a
checksum error. Lights when there’s a non-zero FEBE value (1–8) in the
most significant nibble of the G1 octet of the STS-12c/STM-4c overhead.
(SDH REI = equivalent SDH term)
5: Monitoring the ATM Network
5.2 Monitoring an OC-12c/STM-4c Interface
75
Summary of Contents for 622Vu Advisor
Page 1: ...Agilent Technologies 622Vu Advisor User s Guide ...
Page 6: ...vi ...
Page 54: ...3 Getting Started 3 4 Setting Up User Profiles 54 ...
Page 66: ...4 Configuring Analysis Devices 4 2 Configuring an OC 12c STM 4c Device 66 ...
Page 116: ...6 Capturing Incoming Traffic 6 3 Viewing Captured Traffic 116 ...
Page 130: ...7 Monitoring Real Time Statistics 7 4 Creating A FilterSet That Captures Specific VCCs 130 ...
Page 152: ...8 Filtering Captures 8 6 Advanced Filtering Mode 152 ...
Page 180: ...10 Running Editing Scripts 10 2 Creating or Editing a Script 180 ...
Page 224: ... A Glossary 224 ...
Page 228: ...C Summary of Libraries 228 ...
Page 230: ...230 ...
Page 233: ...Declaration of Conformity 233 ...
Page 234: ...234 ...
Page 244: ...244 ...