![Agilent Technologies 622Vu Advisor User Manual Download Page 178](http://html.mh-extra.com/html/agilent-technologies/622vu-advisor/622vu-advisor_user-manual_2867918178.webp)
Defining the Specifics of the Script
The Script Steps panel lists all the steps in the script, in order as transmitted
during execution. There’s a repeat count for each step. You’ll use this area to
add or remove a step from the script, or to select a step to be modified.
Steps in the script, listed
in order as exectuted
when the script runs.
Click any step to edit its
content, or to shift it up
or down in the script.
Click the appropriate
button to shift the
selected step up or
down in the script.
Click to delete the
selected step.
Click to save the current step’s
definition (after changes).
Click to add a new
step to the script.
Use the buttons in this area to specify the type of processing you want:
Click
To…
Add
Add a new step to the script, positioning it just after the currently selected step.
Update
Revise the definition of the currently selected step.
Remove
Remove the selected step. 622Vu Advisor verifies your request before deleting the
step.
Up
Shift the currently selected step up one position in the script.
Down
Shift the currently selected step down one position in the script.
Each script begins with a Start step and ends with an End step. You can add any
combination of transmit and pause steps between these special markers. The top
of the Script Steps panel defines the currently selected step, or a new step you’re
defining.
Adding or Updating a Step in the Script
For a new or modified step, use the top of the Script Steps panel to define the
characteristics of the step. As identified by the Type field, each step is either a
Transmit (which sends a sequence out from the analysis device) or a Pause
(which pauses a specified amount of time).
When you’re through defining the characteristics of the step, click Add to add
the specifications as a new step, placing it just below the step that’s selected;
click Update to modify the currently selected step.
10: Running & Editing Scripts
10.2 Creating or Editing a Script
178
Summary of Contents for 622Vu Advisor
Page 1: ...Agilent Technologies 622Vu Advisor User s Guide ...
Page 6: ...vi ...
Page 54: ...3 Getting Started 3 4 Setting Up User Profiles 54 ...
Page 66: ...4 Configuring Analysis Devices 4 2 Configuring an OC 12c STM 4c Device 66 ...
Page 116: ...6 Capturing Incoming Traffic 6 3 Viewing Captured Traffic 116 ...
Page 130: ...7 Monitoring Real Time Statistics 7 4 Creating A FilterSet That Captures Specific VCCs 130 ...
Page 152: ...8 Filtering Captures 8 6 Advanced Filtering Mode 152 ...
Page 180: ...10 Running Editing Scripts 10 2 Creating or Editing a Script 180 ...
Page 224: ... A Glossary 224 ...
Page 228: ...C Summary of Libraries 228 ...
Page 230: ...230 ...
Page 233: ...Declaration of Conformity 233 ...
Page 234: ...234 ...
Page 244: ...244 ...