For New and Edit processing, proceed to Section 9.4 Defining the Cells In a
Sequence.
Note: As an alternative to defining a sequence’s cell content, you can use the AAL5 wizard,
described next.
9.3 Using the AAL5 Wizard
The AAL5 wizard lets you define AAL5 PDUs
easily, without concern for accurate SAR and
CPCS settings, and without having to compute
the CRC. From 622Vu Advisor’s main menu, choose Cell Sequence AAL
Wizards - AAL5 from the Tools menu to start the wizard:
Master property values
(inherited by any cells for
which the corresponding
property is undefined).
Click to display a list of
sequences, to append the
new PDU at the end of an
existing sequence.
Sequence where you want
to store the new AAL5
PDU. Enter a new or
existing sequence name.
Indicate whether you want to
define the PDU cell-by-cell,
using the Cell Editor; or from
a file stored on your PC.
Use with the Cell Editor to define (or modify)
the previous or next cell in the PDU.
Character with which to
fill unassigned positions
in the new PDU.
Use when importing the PDU from a text file to open a Windows
Open dialog box (from which you can then select the file you want).
Number of cells created
with the editor.
In the top-most panel, enter either the name of a new sequence (to start a new
definition) or the name of an existing sequence (to append the PDU at the end of
an existing sequence). In the latter case, you can click the Select button to
display a list of sequences that exist already, to choose the one you want.
Use the middle panel to specify the master sequence values, as described starting
on page 158. For ease of processing, the
<Enter>
key tabs between the header
fields indefinitely, as long as you stay in the Header area. Specify fields using
9: Editing Transmit Sequences
9.3 Using the AAL5 Wizard
160
Summary of Contents for 622Vu Advisor
Page 1: ...Agilent Technologies 622Vu Advisor User s Guide ...
Page 6: ...vi ...
Page 54: ...3 Getting Started 3 4 Setting Up User Profiles 54 ...
Page 66: ...4 Configuring Analysis Devices 4 2 Configuring an OC 12c STM 4c Device 66 ...
Page 116: ...6 Capturing Incoming Traffic 6 3 Viewing Captured Traffic 116 ...
Page 130: ...7 Monitoring Real Time Statistics 7 4 Creating A FilterSet That Captures Specific VCCs 130 ...
Page 152: ...8 Filtering Captures 8 6 Advanced Filtering Mode 152 ...
Page 180: ...10 Running Editing Scripts 10 2 Creating or Editing a Script 180 ...
Page 224: ... A Glossary 224 ...
Page 228: ...C Summary of Libraries 228 ...
Page 230: ...230 ...
Page 233: ...Declaration of Conformity 233 ...
Page 234: ...234 ...
Page 244: ...244 ...