Analysis Tab
Use the Analysis tab to specify:
•
The maximum acceptable
percentage of errored cells. This is
the highest percent of cells that can
show up as errored in any single
block, before the block is marked as
severely errored. (The detailed
statistics for the test include Cells
Errored and Blocks Errored fields.)
•
The maximum acceptable variation
in cell-delay times (CDV). This is the maximum acceptable amount of delay
between the arrival of any two sequential cells. If the delay exceeds the
number of microseconds specified here at any point in time, the session
continues to run, but the analysis device increments two statistics: Cells with
Bad CDV and Late Cells.
•
The maximum amount of time to wait for the arrival of the initial cells in any
given test, before the session times out. Specify this time-out value either as
Infinite (no timeout) or a number of seconds.
Generation and Analysis Mode Settings
When running in Generation and Analysis mode, there are two tabs in the
Options panel.
•
The Execution tab defines options related to execution of the session, and is
specified exactly the same as the Execution tab for Generation (only) mode
sessions. Refer to Generation (only) Mode Settings (page 193) for
instructions to fill in this tab.
•
The Analysis tab defines options related to the receipt and analysis of session
data, and is specified exactly the same as the Analysis tab for Analysis (only)
mode sessions. Refer to Analysis Tab (page 195), for instructions to fill in
this tab.
12: Using QoSMeter
12.2 Defining a Constant Bit Rate (CBR) Session
195
Summary of Contents for 622Vu Advisor
Page 1: ...Agilent Technologies 622Vu Advisor User s Guide ...
Page 6: ...vi ...
Page 54: ...3 Getting Started 3 4 Setting Up User Profiles 54 ...
Page 66: ...4 Configuring Analysis Devices 4 2 Configuring an OC 12c STM 4c Device 66 ...
Page 116: ...6 Capturing Incoming Traffic 6 3 Viewing Captured Traffic 116 ...
Page 130: ...7 Monitoring Real Time Statistics 7 4 Creating A FilterSet That Captures Specific VCCs 130 ...
Page 152: ...8 Filtering Captures 8 6 Advanced Filtering Mode 152 ...
Page 180: ...10 Running Editing Scripts 10 2 Creating or Editing a Script 180 ...
Page 224: ... A Glossary 224 ...
Page 228: ...C Summary of Libraries 228 ...
Page 230: ...230 ...
Page 233: ...Declaration of Conformity 233 ...
Page 234: ...234 ...
Page 244: ...244 ...