For each bit position, specify one of the values below, combining the 1s and 0s
into hexadecimal characters for purposes of data entry (e.g., entering four 1s as a
single hex F). Use hexadecimal if the Options menu Show Header Values in
Decimal Format setting is OFF; decimal if it is ON:
Bit (s)
Setting
Tells 622Vu Advisor…
0 (zero)
Ignore this bit position; it’s not relevant to the filter.
1
Examine this bit position. Store the cell in this filterset if all positions corre-
sponding to 1s in the mask contain the values (0 or 1) specified in the same bit
positions in a filter entry.
X
Ignore all the bits in this field. If you use Xs in a field, the entire field must specify
Xs.
By default (i.e., if you’re not using advanced masking), 622Vu Advisor looks at
the first 28 bit positions of each header (the GFC, VPI, and VCI fields). With
advanced masking, it examines the first 48 bits (also the PTI, CLP, HEC, and
first byte of the payload).
Change the mask as necessary, to
indicate those bit positions you want
to examine (mask value is 1), and
those you want to ignore (mask
value is 0). In the example shown to the right (and the corresponding bit mask
shown below), we’re asking 622Vu Advisor to look at the 1-bit CLP:
FilterSet
Mask
Bit:
Byte 5
Byte 1
Byte 2
Byte 3
Byte 4
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
Payload Byte 1
8 7 6 5 4 3 2 1
1 X X X X X X X X
X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
HEC
VCI
PTI
GFC
VPI
CLP
Payload
Filter Entries in Advanced Filtering Mode
With Advanced Filtering Mode on, the filter-entry window lets you specify
selection criteria based on all the header fields, as well as the first byte position
of the payload. Any fields you’ve instructed 622Vu Advisor to ignore are grayed
out in the Filter Match area, and shouldn’t be entered.
Use the other character positions to specify bit values you want to match to
incoming cells:
8: Filtering Captures
8.6 Advanced Filtering Mode
150
Summary of Contents for 622Vu Advisor
Page 1: ...Agilent Technologies 622Vu Advisor User s Guide ...
Page 6: ...vi ...
Page 54: ...3 Getting Started 3 4 Setting Up User Profiles 54 ...
Page 66: ...4 Configuring Analysis Devices 4 2 Configuring an OC 12c STM 4c Device 66 ...
Page 116: ...6 Capturing Incoming Traffic 6 3 Viewing Captured Traffic 116 ...
Page 130: ...7 Monitoring Real Time Statistics 7 4 Creating A FilterSet That Captures Specific VCCs 130 ...
Page 152: ...8 Filtering Captures 8 6 Advanced Filtering Mode 152 ...
Page 180: ...10 Running Editing Scripts 10 2 Creating or Editing a Script 180 ...
Page 224: ... A Glossary 224 ...
Page 228: ...C Summary of Libraries 228 ...
Page 230: ...230 ...
Page 233: ...Declaration of Conformity 233 ...
Page 234: ...234 ...
Page 244: ...244 ...