Interface Management
3.3 /PRI Interface Configuration Commands
3.3.1 cable (/PRI Interface)
Syntax
cable
{
long
{
0db
|
-7.5db
|
-15db
|
-22.5db
}
|
short
{
133ft
|
266ft
|
399ft
|
533ft
|
655ft
} }
undo cable
View
/PRI interface view
Parameter
long
: Match a transmission cable of 655 feet and above. The options for this
parameter include
0db
,
-7.5db
,
-15db
and
-22.5db
. The attenuation parameter is
selected depending on the quality of the signal received at the receiving end. In this
case, no external CSU is needed.
short
: Match a transmission cable shorter than 655 feet. The options for this
parameter include
133ft
,
266ft
,
399ft
,
533ft
and
655ft
. The length parameter is
selected depending on the corresponding length of the transmission cable.
Description
Using the
cable
command, you can configure the attenuation or length of a
transmission cable that the /PRI interface matches. Using the
undo cable
command,
you can restore the default value.
By default, the attenuation of transmission cable that the /PRI interface matches is
long
0db
.
This command is mainly used to configure the signal waveform at the time of
transmission to satisfy various transmitting requirements. In practice, the quality of
the signal received by the receiving end determines whether this command will be
used. If the signal quality is relatively good, use the default setting. In this case, the
/PRI interface does not need an external CSU device.
Example
# Set the length of the transmission cable that the /PRI interface matches to 133 feet.
[3Com-T1-0]
cable short 133ft
41
Summary of Contents for 3C13612
Page 1: ...3Com Router Command Reference Guide V1 00 http www 3com com Part No Published August 2003 ...
Page 199: ...3Com Router Command Reference Guide V1 00 8 1 36 reset stp statistics 167 6 ...
Page 456: ...3Com Router Command Reference Guide V1 00 Quidway reset ipx statistics 96 ...
Page 493: ...Routing Protocol 6 1 10 ip policy route policy 137 5 ...