undo
ft1
loopback
[
local
|
remote
]
View
T1-F interface view
Parameter
local
:
Places the interface in local loopback.
remote
:
Places the interface in remote loopback.
Description
Using the
ft1 loopback
command, you can configure a T1-F interface in local or
remote loopback. Using the
undo ft1 loopback
command, you can disable the local
and remote loopbacks on the interface.
By default, the interfaces are not placed in local or remote loopback.
Local loopback and remote loopback are used for testing the state of interface or
cable itself. These functions should be disabled in normal cases. On an interface,
using this command but with different arguments can respectively enable local
loopback and remote loopback, but these two functions cannot be enabled at the
same time.
Example
# Place the T1-F interface in local loopback.
[3Com-Serial0]
ft1 loopback local
3.5.7 ft1 timeslot-list
Syntax
ft1
timeslot-list
{
all
|
range
} [
speed
{
56
|
64
} ]
undo
ft1
timeslot-list
View
T1-F interface view
Parameter
all
:
Binds all the time slots on an interface. The interface rate will become 24 X
64kbps (that is, 1536kbps) after binding.
range
:
Time slots participating in the binding operation. It is in the range of 1 to 24.
When specifying time slots for binding, you can configure a single time slot by using
58
Summary of Contents for 3C13612
Page 1: ...3Com Router Command Reference Guide V1 00 http www 3com com Part No Published August 2003 ...
Page 199: ...3Com Router Command Reference Guide V1 00 8 1 36 reset stp statistics 167 6 ...
Page 456: ...3Com Router Command Reference Guide V1 00 Quidway reset ipx statistics 96 ...
Page 493: ...Routing Protocol 6 1 10 ip policy route policy 137 5 ...