3Com Router Command Reference Guide — V1.00
Parameter
master
:
Internal clock is used.
slave
:
Line clock is used.
Description
Using the
ft1 clock
command, you can configure clock used by an E1-F or T1-F
interface. Using the
undo ft1 clock
command, you can restore the default clock of
the interface.
By default, the interfaces use
slave
clock.
For a T1-F interface used as DCE,
master
clock should be used. If the interface is
used as DTE, however,
slave
clock should be used.
Example
# Set the T1-F interface to use internal clock.
[3Com-Serial0]
ft1 clock master
3.5.4 ft1 code
Syntax
ft1 code
{
ami
|
b8zs
}
undo ft1 code
View
T1-F interface view
Parameter
ami
:
Adopts AMI line code format.
b8zs
: Adopts B8ZS line code format.
Description
Using the
ft1 code
command, you can configure line code format for a T1-F interface.
Using the
undo ft1 code
command, you can restore the default line code format of
interface.
By default, T1-F interfaces adopt
b8zs
.
The line code of an interface should be set in consistency with that of the peer.
56
Summary of Contents for 3C13612
Page 1: ...3Com Router Command Reference Guide V1 00 http www 3com com Part No Published August 2003 ...
Page 199: ...3Com Router Command Reference Guide V1 00 8 1 36 reset stp statistics 167 6 ...
Page 456: ...3Com Router Command Reference Guide V1 00 Quidway reset ipx statistics 96 ...
Page 493: ...Routing Protocol 6 1 10 ip policy route policy 137 5 ...