3Com Router Command Reference Guide — V1.00
View
System view
Parameter
minutes
: Time interval for counting of traffic at all interfaces, in minutes. Ranging from
1 to 10 minutes. By default,
minutes
is 5 minutes.
Description
Using the
flow-interval
command, you can configure the time interval for counting
traffic at all interfaces.
The system keeps statistics on traffic at every time interval to calculate traffic per time
unit for the sake of reference. This parameter
minutes
has effects on other flow
control methods including the
dialer threshold
command. This command is used to
set the time interval for counting traffic at all interfaces.
For related commands, see
display interfaces
,
reset counters interface
.
Example
# Set the time interval for counting traffic at all interfaces to 2 minutes.
[3Com]
flow-interval 2
1.1.5 interface
Syntax
interface type number
[ .
sub-number
]
undo interface type number
[ .
sub-number
]
View
All views
Parameter
type
: Type of interface. The interface types supported by the operating system at
present are shown in Table 1-2.
number
: Number of the interface. The operating system numbers all the interface
types of the router. The number of the interface for each interface type starts from 0
or 1.
sub-number
: Sub interface number. Range from 0 to 4294967295.
8
Summary of Contents for 3C13612
Page 1: ...3Com Router Command Reference Guide V1 00 http www 3com com Part No Published August 2003 ...
Page 199: ...3Com Router Command Reference Guide V1 00 8 1 36 reset stp statistics 167 6 ...
Page 456: ...3Com Router Command Reference Guide V1 00 Quidway reset ipx statistics 96 ...
Page 493: ...Routing Protocol 6 1 10 ip policy route policy 137 5 ...