ZP3 Fire Control Panel
System Overview
ZP3 Fire Control Panel Manual
Page 1 - 16
UD1160.1 Iss 6 (25/02/2005)
I
1
1.2.8 Peer-to-Peer Networking
Using Ziton's "ZP-NET" system, up to 255 ZP3 systems (verified up to 100 ZP3 systems)
can be connected together in a peer-to-peer network, creating an integrated multi-panel
system with system-wide alarm reporting, co-ordinated evacuation, cause-and-effect
functionality and control, for large systems.
In addition to ZP3 panels, the network can include one or more "Maestro" graphics display
computers. Display and control functions are fully programmable, and alarms and events,
including zone, location, and point messages, can be programmed to display from any
source panel onto any other panel in the network. Alarm mapping is available across the
network, and alarms from any control panel can be programmed to operate
sounders/outputs on other panels.
One or more panels can be assigned as system masters, and can display the status of the
complete system. "Maestro" graphics display computers also show the status of all panels in
the network, and operate as masters, allowing remote operation of all panels in the network.
Network communication is connected via the Z-Net port in each panel. This is a RS485 port,
and the network can be either 2-core shielded copper-wire connection, or fibre-optic. RS485
wire connection can be up to 2000 metres, and the fibre-optic connection up to 30
kilometres.
GRAPHIC SYSTEMS
REMOTE DIAGNOSTICS
DIAL-IN
CONNECTION
TELEPHONE CABLE
Z-NET
MODEM
MODEM
ZP3 PANEL
ZP3 PANEL
ZP3 PANEL
ZP3 PANEL
COPPER WIRE
FIBRE OPTICS
Содержание ZP3
Страница 1: ...ZITON ZP3 Fire Control Panel Installation Operation Maintenance...
Страница 2: ......
Страница 10: ......
Страница 11: ...ZP3 Fire Control Panel Installation Manual Section 1 System Overview UD1160 1 Issue 6 25 02 2005...
Страница 12: ......
Страница 29: ...ZP3 Fire Control Panel Installation Manual Section 2 ZP3 Panel UD1160 2 Issue 6 25 02 2005...
Страница 30: ......
Страница 63: ...ZP3 Fire Control Panel Installation Manual Section 3 Power Supply UD1160 3 Issue 6 25 02 2005...
Страница 64: ......
Страница 81: ...ZP3 Fire Control Panel Installation Manual Section 4 Installation UD1160 4 Issue 6 25 02 2005...
Страница 82: ......
Страница 91: ...ZP3 Fire Control Panel Installation Manual Section 5 Field Wiring UD1160 5 Issue 6 25 02 2005...
Страница 92: ......
Страница 106: ......
Страница 107: ...ZP3 Fire Control Panel Installation Manual Section 6 Software Programming UD1160 6 Issue 6 25 02 2005...
Страница 108: ......
Страница 114: ...ZP3 Fire Control Panel Software Programming ZP3 Fire Control Panel Manual Page 6 6 UD1160 6 Iss 6 25 02 2005 I6...
Страница 115: ...ZP3 Fire Control Panel Software Programming ZP3 Fire Control Panel Manual UD1160 6 Iss 6 25 02 2005 Page 6 7 I6...
Страница 128: ......
Страница 129: ...ZP3 Fire Control Panel Installation Manual Section 7 System Configuration UD1160 7 Issue 6 25 02 2005...
Страница 130: ......
Страница 143: ...ZP3 Fire Control Panel Installation Manual Section 8 System Commissioning UD1160 8 Issue 6 25 02 2005...
Страница 144: ......
Страница 149: ...ZP3 Fire Control Panel Installation Manual Section 9 Peer to peer 3 Protocol UD1160 9 Issue 6 25 02 2005...
Страница 150: ......
Страница 158: ......
Страница 159: ...ZP3 Fire Control Panel Installation Manual Operator Instructions UD1160 O Issue 6 25 02 2005...
Страница 160: ......
Страница 189: ...ZP3 Fire Control Panel Installation Manual Maintenance UD1160 M Issue 6 25 02 2005...
Страница 190: ......
Страница 209: ...ZP3 Fire Control Panel Maintenance ZP3 Fire Control Panel Manual UD1160 M Iss 6 25 02 2005 Page 1 19 IM...
Страница 214: ......
Страница 215: ...ZP3 Fire Control Panel Installation Manual Appendix E EN54 Setup Requirements UD1160 E Issue 6 25 02 2005...
Страница 216: ......
Страница 219: ...ZP3 Fire Control Panel Installation Manual Appendix W ZP Wiring Guide UD1160 W Issue 6 25 02 2005...
Страница 220: ......