1
+10V ref
2
AI1 +
3
AI1 -
4
AI2 +
5
AI2 -
6
+24V out
7
GND
8
DIN1
9
DIN2
10
DIN3
11
CM
12
+24V out
13
GND
14
DIN4
15
DIN5
16
DIN6
17
CM
18
AO1 +
19
AO1 -
30
+24V in
A
RS485
B
RS485
21
RO1
22
RO1
23
RO1
24
RO2
25
RO2
26
RO2
32
RO3
33
RO3
0
AUTO
MAN
2-WIRE
TRANSMITTER
P
I
PRESSURE
SENSOR 1
1S1
2
4
1
3
Reference voltage
NOT USED
(0...10V)
PID FEEDBACK
(4...20mA)
24V auxilary voltage out
I/O ground
START FORWARD
FLUSHING
(Start F Flushing Freq.)
PID SETPOINT SELECT.
(Open=Keypad SP1, Closed=Keypad SP2)
Common for DI1-DI6
24V auxilary voltage out
I/O ground
FAULT RESET
PUMP INTERLOCK
(Not in use by default)
EXTERNAL FAULT
Common for DI1-DI6
OUTPUT FREQUENCY
(0...20mA)
24V auxilary voltage in
Drive-To-Drive
Communication
(Modbus RTU)
Relay Output 1
(RUN)
Relay Output 2
(FAULT)
Relay Output 3
(READY)
0
AUTO
MAN
2-WIRE
TRANSMITTER
P
I
PRESSURE
SENSOR 2
2S1
2
4
1
3
0
AUTO
MAN
3S1
2
4
1
3
2-WIRE
TRANSMITTER
P
I
PRESSURE
SENSOR 3
FLOAT
GND
DIO´S
U
I
AI1
U
I
AI2
U
I
AO
OFF
ON
RS485
termination
FLOAT
GND
DIO´S
U
I
AI1
U
I
AI2
U
I
AO
OFF
ON
RS485
termination
FLOAT
GND
DIO´S
U
I
AI1
U
I
AI2
U
I
AO
OFF
ON
RS485
termination
1
+10V ref
2
AI1 +
3
AI1 -
4
AI2 +
5
AI2 -
6
+24V out
7
GND
8
DIN1
9
DIN2
10
DIN3
11
CM
12
+24V out
13
GND
14
DIN4
15
DIN5
16
DIN6
17
CM
18
AO1 +
19
AO1 -
30
+24V in
A
RS485
B
RS485
21
RO1
22
RO1
23
RO1
24
RO2
25
RO2
26
RO2
32
RO3
33
RO3
Reference voltage
NOT USED
(0...10V)
PID FEEDBACK
(4...20mA)
24V auxilary voltage out
I/O ground
START FORWARD
FLUSHING
(Start F Flushing Freq.)
PID SETPOINT SELECT.
(Open=Keypad SP1, Closed=Keypad SP2)
Common for DI1-DI6
24V auxilary voltage out
I/O ground
FAULT RESET
PUMP INTERLOCK
(Not in use by default)
EXTERNAL FAULT
Common for DI1-DI6
OUTPUT FREQUENCY
(0...20mA)
24V auxilary voltage in
Drive-To-Drive
Communication
(Modbus RTU)
Relay Output 1
(RUN)
Relay Output 2
(FAULT)
Relay Output 3
(READY)
1
+10V ref
2
AI1 +
3
AI1 -
4
AI2 +
5
AI2 -
6
+24V out
7
GND
8
DIN1
9
DIN2
10
DIN3
11
CM
12
+24V out
13
GND
14
DIN4
15
DIN5
16
DIN6
17
CM
18
AO1 +
19
AO1 -
30
+24V in
A
RS485
B
RS485
21
RO1
22
RO1
23
RO1
24
RO2
25
RO2
26
RO2
32
RO3
33
RO3
Reference voltage
NOT USED
(0...10V)
PID FEEDBACK
(4...20mA)
24V auxilary voltage out
I/O ground
START FORWARD
FLUSHING
(Start F Flushing Freq.)
PID SETPOINT SELECT.
(Open=Keypad SP1, Closed=Keypad SP2)
Common for DI1-DI6
24V auxilary voltage out
I/O ground
FAULT RESET
PUMP INTERLOCK
(Not in use by default)
EXTERNAL FAULT
Common for DI1-DI6
OUTPUT FREQUENCY
(0...20mA)
24V auxilary voltage in
Drive-To-Drive
Communication
(Modbus RTU)
Relay Output 1
(RUN)
Relay Output 2
(FAULT)
Relay Output 3
(READY)
VACON 100 FLOW
P1.2 Application
= Multipump(MultiDrive)
P3.15.3 Pump ID Number
= 1
P3.15.4 Start & Feedback
= Signals Connected
VACON 100 FLOW
P1.2 Application
= Multipump(MultiDrive)
P3.15.3 Pump ID Number
= 2
P3.15.4 Start & Feedback
= Signals Connected
VACON 100 FLOW
P1.2 Application
= Multipump(MultiDrive)
P3.15.3 Pump ID Number
= 3
P3.15.4 Start & Feedback
= Signals Connected
+
-
0
P
I
2
4
1
3
DRIVE 3
VACON 100 FLOW
P1.2
Application
= Multipump(MultiDrive)
P3.15.3 Pump ID Number
= 3
P3.15.4 Start & Feedback
= Signals Connected
2-WIRE
TRANSMITTER
PRESSURE
SENSOR 3
Reference voltage
NOT USED (0...10V)
OUTPUT FREQUENCY
(0...20mA)
PID FEEDBACK (4...20mA)
24V auxilary voltage out
24V auxilary voltage in
I/O ground
I/O ground
FAULT RESET
EXTERNAL FAULT
START FORWARD
Common for DI1-DI6
Common for DI1-DI6
24V auxilary voltage out
PUMP INTERLOCK
(Not in use by default)
Drive-To-Drive
Communication
(Modbus RTU)
Relay Output 1
(RUN)
Relay Output 2
(FAULT)
Relay Output 3
(READY)
FLUSHING
(Start F Flushing Freq.)
PID SETPOINT SELECT.
(Open=Keypad SP1, Closed=Keypad SP2)
DIO´S
FLOAT
GND
U
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
30
A
B
21
22
23
24
25
26
32
33
RO1
RO1
RO1
RO2
RO2
RO2
RO3
RO3
+10V
ref
AI2+
AI1-
AI2+
AI2-
+24V
out
GND
DIN1
DIN2
DIN3
CM
+24V
out
GND
DIN4
DIN5
DIN6
CM
AO1+
AO1-
+24V
in
RS485
RS485
I
U
I
U
I
OFF
ON
AI1
AI2
AO
RS485
termination
AUTO MAN
3S1
DRIVE 1
DRIVE 2
DRIVE 3
Fig. 20: Electric wiring diagramme of the Multi-pump (multidrive) system, example 1C