TE
752 ms
TF
RF timeout infinite, never expires (factory default)
I0
input inversion disabled (factory default)
I1
input inversion enabled
For
example, if factory default settings are assigned, the reader message is
PRST P0 D0 A2 TF I0
which means that presence without tag reports is disabled, minimum presence true period is 0, RF off
control on timeout or presence false, infinite RF timeout, and input inversion disabled.
530 Display RF0 Filter Status
#530
displays the parameter set for the RF input, including the selected unique ID code
criteria (
#410N
Select Unique ID Code Criteria) and the valid ID code criteria, which
are fixed at one acquisition.
Reader response
RF0S U<0 to 4> V<0 to 3>
where
U0
One ID separation (factory default)
U1
Two ID separations
U2
Three ID separations
U3
Four ID separations
U4
Transmit all IDs
V0
Valid ID code criteria of one acquisition (factory default)
V1
Valid ID code criteria of two acquisitions
V2
Valid ID code criteria of three acquisitions
V3
Valid ID code criteria of four acquisitions
For example, if factory default settings are assigned, the reader message is
RF0S U0 V0
which means separation of one ID for uniqueness filtering and a valid ID code criteria of
one acquisition.
534 Display Tag Translation Mode Status
#534
displays tag translation mode status, enabled or disabled. If tag translation mode is
enabled, incoming full-frame tags in AAR or ATA format are translated according to
ISO standards. Refer to
“452 Disable Tag Translation Mode (Factory Default)” on page
“453 Enable Tag Translation Mode” on page 5–65
Reader response:
TT <0 to 1>
where
0
tag translation mode disabled
1
tag translation mode enabled