Table 28 Error Messages
Error
Message
Description
Corrective Action
ErrorRF3
Warning message of unexpected status
read, including status byte, from RF
module
If the reader indicates a single
#ErrorRF3
event and recovers from the error, no
corrective action is required. You may want
to track this error message if it should occur
again. If the reader indicates repeated
#ErrorRF3
warning messages then return
the reader to the factory.
Troubleshooting
If you contact TransCore Technical Support, use the symptom number in
problem that you are having with the MPRX. Should problems continue, contact TransCore for return and
replacement procedures.
Table 29 Symptoms and Remedies
Symptom
Number
a
Symptom
Remedy
1
When performing a quick
test of the MPRX, the buzz
box does not buzz.
Check all wiring connections and antenna connections and ensure
that the buzz box is functioning.
The wires from the MPRX are grouped in pairs. You may find more
than one red wire, more than one black wire, and so on. Be sure to
connect the correct red and white wire pair to the leads from the
battery.
Verify that RF is on. Using a terminal emulation program, you may
switch to command mode and issue command #527 to determine
RF status.
“527 Display RF Status” on page 5–69
information.
2
The baud rate is selected
correctly but nothing
happens.
The MPRX is not communicating with your host device. Check
the power supply to your host device, and check the connections
between the host device and the MPRX. Try reversing the receive
and transmit connections. Also, check the position of the Interface
Selection Switch.
Chapter 7 Troubleshooting and Maintenance
TransCore Proprietary
7–101
Содержание MPRX 10-7200-001