63 Reset Reader
#63
resets the power fail bit, clears all buffers, resets tag uniqueness, turns off both output
lines, transmits the sign-on message, and returns to the data mode.
Note:
This command does not reset any other configuration parameters.
Reader response:
Model E4 Series Ver X.XX SNSSSSSS
Copyright 2008 TransCore
where
X.XXD
Version number
SSSSSS
Serial number of the unit, skipping the fourth character printed on the reader product
label.
640N RF Control
#640N
directly controls the RF module. The N value controls the RF power as shown in
.
Table 20 RF Control Commands
Command
RF Power
6400
Turns off RF
6401
Turns on RF
Note:
These commands only have an effect when the reader is not in MPRX mode. Refer to
Commands
#836
and
#837
.
#6400
disables RF-by-input control command
#641
Select RF-by-Input Control.
Reader response:
#Done
641 Select RF-by-Input Control (Factory Default)
#
641
configures the reader for RF-by-input control. The reader automatically turns on RF
when it detects a presence through sense 0. The reader turns off RF according to the
selected RF control algorithm (
#692N
Select RF Control Algorithm).
Note:
This command only has an effect when the reader is not in MPRX mode.
Reader response:
#Done
643NN Select ATA Operating Range (Distance)
#643NN
selects the read range for ATA tags where
NN
is a hexadecimal value from 00 to 1F; the
range increases with increasing
NN
value. The range can be adjusted for 32 discrete
values where 00 is the shortest range and 1F is the longest range. The default range
value is 1F.
Reader response:
#Done
MPRX User Guide
TransCore Proprietary
5–76
Содержание MPRX 10-7200-001
Страница 137: ......