Command List
Reader commands are divided into groups based on a primary function. The following sections provide
information about each command in command number order. Refer to
for listings of commands in numerical and alphabetical order.
In the following text, the symbols
<and>
represent variable message data. These symbols are not part of
the message syntax.
Hex digits (0–9, A–F) in either uppercase or lowercase characters may be used in data strings and for hex
digits A–F.
Reader Mode Control — Command Group 0
Group 0 commands control reader mode. The mode determines whether the reader is transmitting data to
or receiving data from a host device or terminal.
00 Switch to Data Mode (Factory Default)
#00
switches the reader to data mode, which allows the reader to transmit tag data (ID
codes) to the host. In addition to switching the reader to data mode, Command
#00
automatically saves to non-volatile memory (NVRAM) any user parameters that had
been changed during the command mode session. The reader enters data mode on
power up.
Caution
To save user parameter changes to non-volatile memory (NVRAM), you must send Command
#00
before powering down the reader.
When MPRX mode has been enabled (
#837
) and while the MPRX is in data mode, the host device can
send the following commands to the MPRX:
#01
Switch to Command Mode
Reader response:
#Done
#440
Reset Uniqueness
Reader response:
#Done
#8110
Switch on RF port 0, Fire Off Check Tag Address 0 on Check Tag pin 0
Reader response:
#Done
#8111
Switch on RF port 1, Fire Off Check Tag Address 1 on Check Tag pin 0
Reader response:
#Done
#8112
Switch on RF port 2, Fire Off Check Tag Address 0 on Check Tag pin 1
Reader response:
#Done
#8113
Switch on RF port 3, Fire Off Check Tag Address 1 on Check Tag pin 1
Reader response:
#Done
#8150
Set Check Tag Address to 0 on Check Tag pin 0.
Reader response:
#Done
MPRX User Guide
TransCore Proprietary
5–58