Table 37 MPRX Commands Listed Numerically
Number
Command Name
Reader Message
543
Display boot checksum
BCKS xxxx
549
Get user-programmable group select equals
(GSE) filter data
The response data is
formatted similar to the
data in the configuration
command.
552
Request sensor status change
MUX x<0 to 3>
<MPRX>
560
Display input status change
SSTC E<0 to 1> M<0
to 3>
570
Display operating mode status
ATA:<E, D> eGo:<I,
F, D> SeGo:<I,
F, D> IAG:<E, D>
Sort:<E, D> TMM0
577
Report buffered handshakes
HDSH C0 <ww> C1
<xx> C2 <yy> C3
<zz>
60NN
Set reader ID number
#Done
6000
Reader ID Number (default)
#Done
610
Select basic protocol (default)
#Done
611
Select ECP protocol
#Done
612NN
Set ECP timeout
#Done
612FE
Set ECP timeout = 12.7 sec (default)
#Done
613
Enable data inquiry protocol
#Done
6140
Disable flow control
#Done
6141
Enable software flow control (default)
#Done
6170
Disable echo mode
#Done
6171
Enable echo mode (default)
#Done