Reset Reader
Command
#63
Reset Reader resets uniqueness, clears the power fail bit, and transmits the sign-on
message. The reader returns to data mode following the completion of this command.
Note:
This command does
not
reset any of the configuration parameters.
Refer to
“63 Reset Reader” on page 5–76.
To reset the reader
1. Ensure that the host device is in command mode.
2. Enter Command
#63
. Press
ENTER.
Radio Frequency
Caution
The authorized continuous wave (CW) frequency band for the MPRX in the U.S. is 902.25
to 903.75 MHz and 910.00 to 921.50 MHz and the authorized modulated frequency band
for the MPRX in the U.S. is 911.75 to 919.75 MHz. The RF for each MPRX at the site must be
set according to the frequency specified in the FCC site license. Only trained, authorized
installation and maintenance personnel are permitted by FCC to set the RF.
By using the MPRX an authorized person can set the frequency within the range from 860 to 930 MHz
in 0.25 MHz steps. You can set the frequency by using a terminal emulation program and issuing the
frequency command, as discussed in section
“647XXX Select RF Operating Frequency” on page 5–77.
Note:
For backward compatibility to existing controllers, you can set the RF operating frequency in
500-kHz steps using Command
#642NN
.
Chapter 6 Configuration
TransCore Proprietary
6–93