#8151
Set Check Tag Address to 1 on Check Tag pin 0.
Reader response:
#Done
#8152
Set Check Tag Address to 0 on Check Tag pin 1.
Reader response:
#Done
#8153
Set Check Tag Address to 1 on Check Tag pin 1.
Reader response:
#Done
Note:
The MPRX transmits ID codes to the host device when the MPRX is in data mode.
01 Switch to Command Mode
#01
switches the reader to command mode, which allows the reader to accept commands
from a host or terminal. While in command mode, the reader turns RF off and does not
acquire tags.
Reader response:
#Done
Communications port Control — Command Group 1
Group 1 commands configure the parameters used by the MPRX to communicate with a host device or
terminal. These commands set baud rate, stop bits, parity, and end-of- line delay.
100N Select Baud Rate
#100N
selects the reader baud rate. The factory-default setting is 9600 baud. The N variable
specifies the baud rate shown in
.
Table 12 Select Baud Rate Commands
Command
Baud Rate Selected
1002
1200
1003
2400
1004
4800
1005
9600 (factory default)
1006
19.2 K
1007
38.4 K
Reader response:
#Done
Caution
If ECP is enabled, ensure that the ECP timeout is sufficient for the new baud rate.
.
101N Select Stop Bits
#101N
selects the number of stop bits for reader character transmission. The factory default
setting is 1 stop bit. The N variable specifies the number of stop bits as indicated in
.
Chapter 5 Commands
TransCore Proprietary
5–59