Chapter 6 Configuration
Configuring the Reader
After installing the MPRX, you need to configure its operating parameters. Terminal settings should be
initially set at 9600 baud, 8 data bits, no parity, 1 stop bit, and no software flow control.
Default Operating Parameter Settings
contains the factory default configuration settings for the MPRX operating parameters. The
default configuration settings may not be the correct operating configuration settings for a specific site.
Review the default configurations shown in
to determine which parameters, in addition to
operating frequency and operating range, need to be adjusted. Refer to
a complete list of parameters and the corresponding commands.
Note:
The dual-protocol MPRX internal timing varies depending on the operative tag read mode
and the type of tag in the read field.
Table 26 MPRX Default Configuration Settings
Parameter
Setting
Command
Operating mode
Data
00
Baud rate
9600
1005
Stop bits
1
1010
Parity
None
1020
Time and date appended
Enabled
302
Auxiliary information appended
Disabled
310
Unique ID code criteria
Separation of 1 ID
4100
Tag translation mode
Disabled
452
SeGo protocol tag initialization
during multi-tag sort
Enabled
456
Reader ID number
00
6000
Communications protocol
Basic
610
Error correcting protocol (ECP)
timeout
12.7 sec
612FE
MPRX User Guide
TransCore Proprietary
6–86
Содержание MPRX 10-7200-001
Страница 137: ......