Appendix D Command Quick Reference
Command Syntax
The command numbers consist of from 2 to 4 hex digits. The letters N or S may follow a command
number. The letter N indicates that part of the command number is variable. The letter S indicates the
requirement for an alphanumeric data string that is to be included immediately following the command
number. Hex digits (0–9, A–F) in either uppercase or lowercase characters may be used in data strings
and for hex digits A–F. For more information refer to
“Chapter 3 General Software Information” on page
lists factory default settings.
lists, in numerical order, all of the commands available to
users.
lists the same commands by command name.
Factory Default Settings
lists the factory default settings for the MPRX.
Table 36 MPRX Default Configuration Settings
Parameter
Setting
Command
Operating mode
Data
00
Baud rate
9600
1005
Stop bits
1
1010
Parity
None
1020
Time and data appended
Enabled
302
Auxiliary information appended
Disabled
310
Unique ID code criteria
Separation of 1 ID
4100
Valid ID code criteria
Acquisition of 1 ID
4200
Uniqueness time-out
2 minutes
441
Tag translation mode
Disabled
452
Multi-tag sort
Disabled
454
SeGo protocol tag initialization
during multi-tag sort
Enabled
456
Reader ID number
00
6000
MPRX User Guide
TransCore Proprietary
D–116
Содержание MPRX 10-7200-001
Страница 137: ......