Table 24 Timeout Period Values
Command
Timeout (ms)
6938
60
6939
92
693A
152
693B
300
693C
452
693D
600
693E
752
693F
Infinite (never expires,
factory default)
Reader response:
#Done
or
#Error.
The reader returns an Error message if a valid hexadecimal digit is not substituted for N in Command
#693N
.
Note:
This command only has an effect when the reader is not in MPRX mode.
694N Select Input Inversion Option
#694N
enables or disables input inversion. When inversion is enabled, an open circuit input
is interpreted as a closed circuit, and a closed circuit input is interpreted as an open
circuit. This feature allows greater flexibility in the attachment of external equipment to
the reader inputs. For example, some proximity sensors indicate presence with an open
circuit. In this instance, Command
#6941
can enable input inversion so that an open
circuit input indicates a presence. The values for N represent the two inversion options
Reader response:
#Done
Table 25 Input Inversion Options
Command
Option
6940
Disable input inversion (factory default)
6941
Enable input inversion
695S...S Set Serial Number (Factory Default)
#
695
assigns the reader serial number according to the format:
695SSSSSS
where
SSSSSS
is the serial number.
MPRX User Guide
TransCore Proprietary
5–80