P2
odd parity
D0
00 ms end-of-line delay (fixed)
One space is required between each value. For example, if factory default settings are assigned, the
reader message is
MAIN B5 S0 P0 D0
indicating 9600 baud, one stop bit, no parity, and 0-ms end-of-line delay.
Note:
The information transmitted in response to Command
#522
applies to data and command
mode operation only. While operating in download mode, default communications parameters are
always used.
524 Display Appended Information Status
#524
displays the information being appended to the reader transmissions. Command
#31N
appends information.
Reader response:
IDAP T<0 to 1> D<0 to 1> X<0 to 1>
where
T0
Time not appended
T1
Time appended
D0
Date not appended
D1
Date appended
X0
Auxiliary information not appended (factory default)
X1
Auxiliary information appended
One space is required between each value. For example, if factory-default settings are
assigned, the reader response is
IDAP T1 D1 X0
indicating time and date appended, and auxiliary information not appended.
525 Display Communications Protocol Status
#525
displays the status of Command
#610
Select Basic Communications Protocol,
Command
#611
Select Error Correcting Protocol, or
#613
Enable Data Inquiry
Protocol, Command
#614N
Selected Mode of Software Flow Control
,
and Command
#612NN
Error Correcting Protocol Timeout
.
Reader response:
ECPS P<0 to 2> T<01 to FF> X<0 to 2> S0
where
P0
Basic protocol selected (factory default)
P1
ECP enabled
P2
data inquiry protocol enabled
Txx
ECP timeout where
xx
= 01 to FE (hexadecimal) |
Timeout (ms) = 50 * xx
If xx = FF timeout disabled
MPRX User Guide
TransCore Proprietary
5–68