![TransCore MPRX 10-7200-001 Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/transcore/mprx-10-7200-001/mprx-10-7200-001_user-manual_1151156065.webp)
#443
30 seconds
Entering these commands effectively expires the timeout clock, which erases all current IDs in the
comparison register. In effect, the first ID that is acquired after the clock expires always appears to be new
and is stored. Newly acquired IDs are only tested against IDs that are registered after the clock resets.
The timeout clock is continually reset (does not expire) as long as the reader receives the same tag ID. For
example, assume that the timeout clock is set for two minutes and there is a railcar parked on a siding in
front of the reader. Without this reset feature, the railcar’s ID would be reported every two minutes (each
time the timeout clock expired).
452 Disable Tag Translation Mode (Factory Default)
#452
disables tag translation mode. Incoming full-frame tags will be converted directly to
ASCII. They will not be translated from Association of American Railroads (AAR) and
American Trucking Associations (ATA) format to ASCII.
Reader response:
#Done
453 Enable Tag Translation Mode
#453
enables the translation of tags in AAR and ATA formats. Specific data fields, such as
owner ID and car number, will be extracted from these tags, translated according to
AAR or ATA standards, and converted to ASCII. Tags that are not programmed in AAR or
ATA format will be converted directly to ASCII. The reader will not attempt to translate
data from half-frame or dual-frame tags.
Reader response:
#Done
454 Disable Multi-tag Sort (Factory Default)
#454
Disables the multi-tag sort function.
Reader response:
#Done
455 Enable Multi-tag Sort
#455
enables the multi-tag sort function that allows the reader to identify unique tags within a
group.
Reader response:
#Done
Note:
Enabling the multi-tag sort function adversely affects the vehicle speed at which tags may be
read. If there is only one tag expected in the vehicles of the target population, multi-tag sort should
be disabled.
456 Enable SeGo Protocol Tag Initialization During Multi-tag Sort (Factory
Default)
#456
enables the reader to send the Super eGo® (SeGo) protocol tag initialize command
as part of the multi-tag sort function. When the reader sends the SeGo protocol tag
initialize command, all tags in the RF field reenter the sort process.
Reader response:
#Done