Installation manual
For Handi-Lift ML7
Original Version
Страница 1: ...Installation manual For Handi Lift ML7 Original Version...
Страница 2: ...Install the tower 4 3 1 Tower positioning 4 Installing the lift unit 7 4 1 Attach the back frame to the tower 7 4 2 Connect the electrical 8 4 3 Connect the platform to the back frame 9 4 4 Connect th...
Страница 3: ...ponds to the installation site 1 2 Electrical installation If the drawing does not show where to install the Control boxes please sort out where they all go Make sure that the electrical supply and el...
Страница 4: ...0x90mm Class 8 8 Glue bolts Two bolts in the wall and three in the floor The given load forces applies for the total force when two bolts are used both places Please make sure the wall and floor mater...
Страница 5: ...anding see fig 3 The distance between the centre of the tower and the landing wall is given on the installation drawing You will also find the distance labelled on the bottom face of the tower The cen...
Страница 6: ...6 Version 1 2 Finally adjust the tower to be vertical in both directions before fixing it to the wall and the floor so the landing fits Mount the bolts in the wall with glue as described on the glue...
Страница 7: ...ge 7 Version 1 2 Installing the lift unit 4 1 Attach the back frame to the tower Place the back frame of the lift on the floor in front of the tower Fig 5 Connectors and cables are put through the hol...
Страница 8: ...Fasten the back frame using the four screws and washers Fig 7 4 2 Connect the electrical Leave the lift carriage and back frame in the lower position of the tower Place the platform on the floor in fr...
Страница 9: ...back frame Mount the platform to the back frame using the two screws and nuts M12x160 M12x180 If necessary adjust the lower position of the platform using the set screws Fig 10 Plug the remote lead i...
Страница 10: ...Page 10 Version 1 2 Now install the control boxes Adjust the limit switches as shown in the photo Fig 12 4 4 Connect the power Fig 13 The wires are connected to the safety cut out as follows L1 is con...
Страница 11: ...the lift with max load Ex 300 kg 50kg The load cell is adjusted from the factory however if it is necessary to adjust it it is done by turning the load cell sensor This is installed at the upper cross...
Страница 12: ...laces you need to install the international Handicap Symbol ISO 7000 with a minimum size of 50 mm next to each control box See picture below Filling oil It is important that you fill oil on the unit h...
Страница 13: ...Handi Lift ML7 2021 Page 13 Version 1 2 Final touch Install the back cover if there is a gate you need to install it before the back cover see chapter 7 Fig 15 Examples of an installation...
Страница 14: ...losed position If the gate is not in closed position on receipt then there is a mark on the foot plate that indicates which position is closed On the installation drawing you can see where to place it...
Страница 15: ...2021 Page 15 Version 1 2 The gate can be connected to the lift in two different ways Hole in the floor No hole use slot in foot plate Fig 18a Fig 18b Connect the plug from the lift with the plug from...
Страница 16: ...age 16 Version 1 2 Make sure the gate is flush with the edge of the floor and then glue and tighten the M10x90 glue bolts Fig 20 Now you are ready to test the gate Make sure it can open and close prop...
Страница 17: ...__ Manufacturer CAMA Lift ApS Ellehammervej 6 DK 9900 Frederikshavn Contract electrical supply _________ V _________ Phase _________ Hz Mains supply fuse rating _________ A Verification test on each m...
Страница 18: ...sting of the overload detection device for wheelchair platforms only Declaration A I We certify that on ____ ____ ____ this Handi Lift was installed to the latest installation instructions and thoroug...