6-12
INSTALLATION-PCB
SECTION 400-096-206
SEPTEMBER 1992
BACKPLANE CONNECTOR
50-PIN AMPHENOL CONNECTOR (FEMALE)
SSTU
SUBUNIT
W1
H
L
W1 Ring Voltage
H = 190V P-P
L = 130V P-P
(For PSTU ( )
and PSTU2 only)
V.4
TABLE 6-C
PSTU CONTROLS
CONTROL (Figure 6-6)
TYPE OF COMPONENT
DESCRIPTION
Ring Voltage W1 Jumper
Plug (PSTU1 ( ) and
PSTU2 only)
3-terminal jumper
Sets ring generator voltage level for all
circuits (V.4 of PSTU1 and PSTU2 only).
H = 190V P-P
L = 130V P-P
V.4
are identical except for the ring generator. The ring
generator on the original version (V.3) of PSTU1 is
fixed at a 190V P-P level, while the ring generator
on PSTU1 (V.4) and PSTU2 can be set for 130V P-
P or 190V P-P. The W1 jumper plug is used to set
the voltage level. Most standard telephones and
two-wire devices require the 190V P-P level; how-
ever, some devices may experience ring-trip with
190V P-P and should be set for 130V P-P level.
NOTE:
PSTU1 (V.4) became available in November
1989. PSTU1(V.3) was discontinued.
6.12 Set the PSTU1 (V.4) or PSTU2 ring generator
level as required:
•
W1 set to H (190V P-P).
•
W1 set to L (130V P-P).
•
Two ringers maximum per port (H or L).
6.20 PSTU Installation Procedures
FIGURE 6-7
PSTU AND SUBUNIT (SSTU)
Содержание Strata DK 24
Страница 2: ......
Страница 10: ......
Страница 12: ...INSTALLATION SYSTEM DESCRIPTION SECTION 400 096 202 SEPTEMBER 1992 ...
Страница 42: ......
Страница 72: ......
Страница 102: ......
Страница 110: ......
Страница 144: ...INSTALLATION TELEPHONE SECTION 400 096 207 SEPTEMBER 1992 ...
Страница 164: ......
Страница 166: ...INSTALLATION PERIPHERALS SECTION 400 096 208 SEPTEMBER 1992 ...
Страница 170: ......
Страница 238: ...INSTALLATION WIRING DIAGRAMS SECTION 400 096 209 SEPTEMBER 1992 ...
Страница 300: ......
Страница 302: ...REMOTE ADMINISTRATION MAINTENANCE PROCEDURES SECTION 400 096 600 SEPTEMBER 1992 ...
Страница 372: ......