STRATA DK FAULT FINDING
SECTION 400-096-500
SEPTEMBER 1992
-10-
CHART NO. 3
STATION FAULTS (cont.)
S1
Page 9
From
Replace the
EOCU on the
appropriate PEKU
or PESU, if used, or
replace the PDKU.
YES
NO
END
S2
this and
Page 9
From
Is
it an
OCA fault?
Replace the
appropriate
PEKU, PESU, or PDKU,
if used.
Is
the fault
cleared?
Tag the
defective unit(s)
and return for
repair.
Replace the PCTU,
initialize the system
and reprogram
as required.
Is
the fault
cleared?
S2
This
Page
To
K1
Page 11
From
NO
YES
YES
NO
YES
NO
Call the
Service Center
for assistance.
Is
it an
OCA fault for
all stations on PEKU,
PESU, or PDKU,
if used?
Содержание Strata DK 24