REMOTE ADMINISTRATION & MAINTENANCE PROCEDURES
SECTION 400-096-600
SEPTEMBER 1992
-34-
TABLE RM-AE
PROGRAM 60
SMDR OUTPUT/ACCOUNT CODE DIGIT LENGTH
ACTION
STEP
DISPLAY/PRINTOUT
1
>MODE PROG
P
Enter Program Mode
At the >MODE prompt, enter
PROGCR
2
P 60
P60
Enter Program Number 60
CR
3B
P60 3 1
P60
Press
System prints out "1" if incoming and outgoing calls will be printed on SMDR.
A "0" prints out if only outgoing calls will be printed.
3C
P60 4 06
Set Account Code Digit Length
Enter: Item code 4.
The system displays the number of digits allowed in the account code. Default is
06. Refer to the System Record Sheet and enter the required number of digits
(04 ~ 15), then press
CR
. To change another parameter in this program, enter its
item code. To exit this program, go to Step 4.
Refer to the System Record Sheet and change (to 1 or 0), if required, and
press
CR
. If you wish to change another parameter within this program,
enter its associated item code. To exit this program, go to Step 4.
3D
P60 5 0
4
To Exit Program/Store Data
Press
# # CR
.
3E
P60 6 NNNN
P60 6 NNNN
P60 ##
P
SMDR Toll Calls Only
The system displays the presently selected feature (0~5).The default is 0. Refer
to the System Record Sheet, enter the feature code, press
CR
. To change
another parameter, enter its item code. To exit this program, go to Step 4.
Enter DISA ID Code
The system displays last entered ID code number. Default = Blank. Refer to
the System Record Sheets, enter a new code if desired, then press
CR
.
To change another parameter in this program, enter its associated item code.
To exit this program, go to Step 4.
.
.
Allow SMDR printout.
Enter: Item code 3.
Enter: Item code 5.
Enter: Item code 6.
3A
P60 21
SMDR Threshold Time
Enter: Item code 2.
3F
P60 7 13
Credit Card Call Digit Length
Enter: Item code 7.
The system displays the current digit length. Refer to the System Record Sheet,
enter the desired length, 01~30 digits, then
CR
. To change another parameter in
this program, enter its item code. To exit this program, go to Step 4.
(R4)
The system displays either "0" or "1". "0" indicates the threshold time is set at
1.0 second. "1" indicates 10 seconds. The default is "1".
Refer to the System Record Sheet, enter the correct digit—if it is not already
being displayed—then
CR
. To change another parameter in this program,
Содержание Strata DK 24
Страница 2: ......
Страница 10: ......
Страница 12: ...INSTALLATION SYSTEM DESCRIPTION SECTION 400 096 202 SEPTEMBER 1992 ...
Страница 42: ......
Страница 72: ......
Страница 102: ......
Страница 110: ......
Страница 144: ...INSTALLATION TELEPHONE SECTION 400 096 207 SEPTEMBER 1992 ...
Страница 164: ......
Страница 166: ...INSTALLATION PERIPHERALS SECTION 400 096 208 SEPTEMBER 1992 ...
Страница 170: ......
Страница 238: ...INSTALLATION WIRING DIAGRAMS SECTION 400 096 209 SEPTEMBER 1992 ...
Страница 300: ......
Страница 302: ...REMOTE ADMINISTRATION MAINTENANCE PROCEDURES SECTION 400 096 600 SEPTEMBER 1992 ...
Страница 372: ......