404
Genie Distribution WNET Manual v3
© Tieline Research Pty. Ltd. 2020
ii. In the search text box type
Run
and press
Enter.
iii. Type
CMD
in the
Run dialog
text box and click
OK
.
iv. Type
tracert
, the IP address of the codec you are contacting (i.e.
tracert 203.36.205.163
)
and press the
Enter
key on your keyboard.
22.6
Testing ISDN Connections
To test your ISDN line is working you can dial a standard phone line or your cell-phone number. If
the call is successful this verifies the line is active. To verify ISDN data is being sent you can:
·
Dial a codec you know is connected to an active ISDN line, e.g. another codec in your
network or a Tieline test codec.
·
Dial the test ISDN data number provided by your Telco (when available).
·
Create a program and perform a loopback test by dialing out on the main ISDN number and
receive the call on the auxiliary ISDN number. (
Note:
To create a loopback program create a
2 x Mono or Stereo Peer-to-Peer program and configure a dial only audio stream using your
main ISDN number. For the second audio stream create an answer only audio stream
connection configured for ISDN. If you dial the connection and can hear the audio you are
sending on the return B channel, you have confirmed ISDN data is being sent successfully.
If you dial using a loopback program and a "disconnect" error message similar to the following
image appears, you may have the incorrect
Line Type
configured.
Change the
Line Type
setting and this should hopefully resolve the issue.
On-Demand ISDN Services
If
Sync
appears for approximately 60 seconds when you connect an ISDN line to the codec and
then disappears, or if
Sync
does not appear and you know you are connected to an active ISDN
interface, then the line may have ‘On-demand’ enabled by your Telco. To test this you can dial a
codec on an ISDN line known to be operational. Dial over ISDN and if
Sync
appears after connecting
it indicates the service has now been activated. Disconnect and then dial again. If this dial is
successful ‘On Demand’ is enabled. We recommend you contact your network service provider and
get them to disable ‘On Demand’ to circumvent any possible connection issues.
22.7
Using Answer Routes for Sessionless ISDN Calls
Tieline Genie Distribution, Merlin, Merlin PLUS and ViA audio codecs support multiple connections
using a variety of connection transports such as IP, ISDN and POTS. Tieline codecs support using
Tieline session data, which assists with configuration and routing of multiple incoming calls to
these codecs. In addition, audio ports can be used to successfully route IP calls to your preferred
codec inputs/outputs.
If you are accepting calls from multiple non-Tieline ISDN codecs then you will be making
"sessionless" connections which require the codecs at both ends to be configured with the same
connection settings. In addition you can use “Answer Routes” and 'site-specific' module settings in
Genie Distribution and Merlin PLUS to route incoming calls to specific codec outputs. (Note: Merlin
codecs can also be configured to accept 2 ISDN calls from non-Tieline codecs and would use
similar settings).
Содержание Genie Distribution
Страница 27: ...27 Tieline Research Pty Ltd 2020 Genie Distribution WNET Manual v3 Connect Menu...
Страница 50: ...50 Genie Distribution WNET Manual v3 Tieline Research Pty Ltd 2020 2 Select Yes and press the button...
Страница 126: ...126 Genie Distribution WNET Manual v3 Tieline Research Pty Ltd 2020...
Страница 365: ...365 Tieline Research Pty Ltd 2020 Genie Distribution WNET Manual v3 IP Connection Bit rates Supported...
Страница 426: ...Genie Distribution WNET Manual v3 426 Tieline Research Pty Ltd 2020 WNET LAN port 15 X XLR in out 15...